 –  ProxTrak Portal Reader Installation Procedure    6042-901-01 Rev 7              
20 of 32
7.3  EEPROM Memory map table
Hex
Dec
Name
Description
Default
$00 - $27
000 
-
039
FT
40 Reserved, 32 used, 8 spare
Factory table - Exciter
$28
040
Red
Red LED Duration byte
$10 - 1.6 Sec (.4 Sec if
"fast" switch is on)
$29
041
Green
Green LED Duration Byte
$10 - 1.6 Sec (.4 Sec if
"fast" switch is on)
$2A
042
Beeper
Beeper Duration Byte
$10 - 1.6 Sec (.4 Sec if
"fast" switch is on)
$2B
043
Relay1
Relay 1 Duration Byte
$10 - 1.6 Sec (.4 Sec if
"fast" switch is on)
$2C
044
Relay2
Relay 2 Duration Byte
$10 - 1.6 Sec (.4 Sec if
"fast" switch is on)
$2D
045
Reserved
$2E
046
Reserved
$2F
047
Failsafe
activation
time
Number of seconds before Failsafe
activation after Comm failure
$1E - 30 Seconds
$30 - $32
048 
-
050
Power up
Indicator
3 bytes to describe the  indicator
status on Power-up
$E4 $55 $00; Two Med Red
Flashes off, Two Med Green
Flashes on, Two Med Beeps
on, Relays off
$33 - $35
051 
-
053
Access read
indicator
3 bytes to describe the indicator
action on an Access Control Read
$02 $23 $88; Short Red
Flash off, Short Green Flash
off, Med Beep on, Relays no
change
$36 - $38
054 
-
056
ProxTrak
read Indicator
3 bytes to describe the indicator
action on an Asset tag Read
$02 $33 $88; Short Red
Flash off, Short Green Flash
on, Short Beep on, Relays
no change
$39 - $3B
057 
-
059
Host Tag
command
performed
3 bytes to describe the indicator
action when a ProxTrak  command
has been executed from the Host
$AC $0D $88; Three Med
Red Flashes off,  Three
Green Med Flashes on,
Three Med Beeps, Relays
no change
$3C - $44
060 
-
068
9 Reserved, 0 used
Spares
$45
069
Switch Block
2 Read and
Report
b0: Set Tamper Latch (Disable
Assets mode) on
b1: Re-report ID's
b2: Indicator re-report
b3: Fast indicators
b4: Acquisition test reports
b5: EEP database
b6: LCD reports
b7: Test LCD installed
$00; Read and Report
options - (Mirror of Switch
Block 2)
$46
070
Switch Block
3 Serial
Configuration
b0: Simplex Serial Output
       (1 = on, 0 = Off)
b2 - b1: Baud  Rate
      11 = 4800      01 = 9600
      10 = 38,400   00 = 19,200
b7 - b3: Node Address
      (00000 - 11111)
$00; Serial Configuration;
(Mirror of Switch Block 3)