HID Global Corporation 6042AA Manuale Utente
_________________________________________________________________________________________
HID Corporation 9292 Jeronimo Road Irvine, CA 92618 USA TEL (949) 598-1600 (800) 237-7769 FAX (949) 598-1690
Web page –
Web page –
www.proxtrak.com
– ProxTrak Portal Reader Installation Procedure 6042-901-01 Rev 7
21 of 32
$47
071
Switch Block
4 Hardware
and Test
Options
4 Hardware
and Test
Options
b0: ProxTrak mode
b1: Access control exciter
b2: Asynchronous acquisition
b3: Status LED's disable
b4: H/W demodulator
b5: Low gain
b6: 8 receivers
b7: 2nd Access Reader
b1: Access control exciter
b2: Asynchronous acquisition
b3: Status LED's disable
b4: H/W demodulator
b5: Low gain
b6: 8 receivers
b7: 2nd Access Reader
$00; Hardware and Test
Options; (Mirror of Switch
Block 4)
Options; (Mirror of Switch
Block 4)
$48
072
FT
Not used
Spare
$49
073
Failsafe Tag
Command
Size
Command
Size
Failsafe Tag Command Size (1
byte)
byte)
$01
$4A - $5B
074
-
091
Failsafe Tag
Command
Command
Failsafe Tag Command Byte(s)
$16;
(Set
Quiet
bit
command)
$5C
092
Default Tag
Command
Size
Command
Size
Tag Command Size (1 byte)
$01
$5D - $6E
093
-
110
Default Tag
Command
Command
Tag Command Byte(s)
$16;
(Set
Quiet
bit
command)
$6F
111
Response
Timeout
Timeout
Reader sends Nothing to Send or
empty Tag ID Message (0 to 23
seconds)
empty Tag ID Message (0 to 23
seconds)
$0B; (1 second)
$70
112
Maui
Timeout Reader activates cycle if Maui
threshold has been exceeded for
this time ( 0 to 25.5 seconds)
this time ( 0 to 25.5 seconds)
$46; (700mS)
$71
113
Maui
Threshold
Threshold
Level required by the interferer to
activate Maui delays (0 to 255)
activate Maui delays (0 to 255)
$FF; ($FF causes Maui to
be disabled)
be disabled)
$72 - $7F
114
-
127
FT
14 Reserved, 10 used
Factory table - Timing and
calibration values
calibration values