$47
071
Switch Block
4 Hardware
and Test
Options
b0: ProxTrak mode
b1: Access control exciter
b2: Asynchronous acquisition
b3: Status LED's disable
b4: H/W demodulator
b5: Low gain
b6: 8 receivers
b7: 2nd Access Reader
$00; Hardware and Test
Options; (Mirror of Switch
Block 4)
$48
072
FT
Not used
Spare
$49
073
Failsafe Tag
Command
Size
Failsafe Tag Command Size (1
byte)
$01
$4A - $5B
074 
-
091
Failsafe Tag
Command
Failsafe Tag Command Byte(s)
$16; 
(Set 
Quiet 
bit
command)
$5C
092
Default Tag
Command
Size
Tag Command Size (1 byte)
$01
$5D - $6E
093 
-
110
Default Tag
Command
Tag Command Byte(s)
$16; 
(Set 
Quiet 
bit
command)
$6F
111
Response
Timeout
Reader sends Nothing to Send or
empty Tag ID Message (0 to 23
seconds)
$0B; (1 second)
$70
112
Maui 
Timeout Reader activates cycle if Maui
threshold has been exceeded for
this time ( 0 to 25.5 seconds)
$46; (700mS)
$71
113
Maui
Threshold
Level required by the interferer to
activate Maui delays (0 to 255)
$FF; ($FF causes Maui to
be disabled)
$72 - $7F
114 
-
127
FT
14 Reserved, 10 used
Factory  table  -  Timing  and