3.3  Mechanical Assembly Procedure
The portal must be assembled in an area where there is at least 96 inches of clearance between the floor
and the ceiling.
Start with the Portal assemblies located near where the Portal will be installed.  The portal will be
assembled on one side and then tipped upright.  It may then be moved into place.
On each major component there will be a red dot indicating the doorway side or edge.
Support the base perpendicular to the floor with the doorway edge up (the doorway edge is the edge
nearest from the crossover wires embedded in the bottom). Stand the Primary Panel assembly on its
entrance edge (the primary panel assembly is the one with the LCD module), red dot up, and fasten it to
the Threshold assembly with the LCD facing towards the inside of the portal. Use 8 of the tapered machine
screws, four in each of the corner supports in the uprights. Repeat for the secondary panel assembly.
Install cross over tubes and route cables as shown in Figure 1
Note - Use precautions to guard against static discharges to any exposed electronics when
handling the Controller assembly.
Place the Controller assembly on its entrance edge and slide the left and right edges onto the Panel
assemblies gray mounting blocks. Note that the fans are located closest to the Primary side. Use the hex
key head 10-20’s (4 each with washers), screwed into the threaded insert in the controller assembly. Add
the 4 1”, 6-32 pan-heads in the through-holes, with the washer and nut on the top, to each gray bracket.
The Portal can now be stood upright. Be sure to lift the top end straight up, without stressing the Portal by
tilting it to the right or left; lift using the lower gray structural pieces.  Do not lift the white antenna
assemblies or the upper gray members. The Portal is not designed to be put into use without structural
support provided at the doorway. (See “Door frame mounting”), below.