Figure 2 Keypad Reader Dimensions and Mounting
2.1 Mullion Mounting
The following describes how the readers mount to a mullion.
1. Drill two holes 6-32 or M-3 sheet metal or thread forming screws 3.3” (8.38 cm) apart.
2. Locate and drill a 0.375” (0.95 cm) hole for the reader cable.
3. Route the cable through the center hole to the controller.
4. Using the two 6-32 or M-3 screws, attach the reader to the first two mounting holes.
5. Once the reader module is screwed in place, snap on the bezel.
3
Wiring
3.1 Cable Types and Maximum Lengths
The MIFARE readers require a minimum voltage of 9.0 VDC. Voltage drops, caused by the cable
resistance, can be made by increasing the power supply voltage.
resistance, can be made by increasing the power supply voltage.
CAUTION: DO NOT SET THE POWER SUPPLY VOLTAGE TO HIGHER THAN 16 VDC.
CAUTION: DO NOT USE CABLES WITH GAUGES SMALLER THAN 24 AWG: