HID Global Corporation X001900 Manuale Utente

Pagina di 193
© 2012 HID Global Corporation.  All rights reserved. 
 
102 
HDP8500 Industrial Card Printer/Encoder  User Guide     L001617 rev 1.1 
Sending the Track Information 
Magnetic track data is sent in the form of text strings from the application software to the Printer 
Driver.  
  In order for the Printer Driver to differentiate between Magnetic Track data and the rest of 
the printable objects, specific characters must be added to the magnetic data to be 
encoded.  
  These specify the data that is to be encoded, the tracks to encode and mark the start and 
stop of the data string.  
  In some cases, these specific characters are automatically added to the string of track data 
by ID software applications.  
  In most cases, the User must carefully add these characters to the string of Magnetic Track 
data. If these characters are not added to the track data, the text intended for the Magnetic 
Track will appear as printed text on the card.  
  To avoid this, track information must be entered as described below. 
Step 
Procedure 
When entering track data, the ~ (tilde) character is entered first, followed by 
the track number (1, 2 or 3) on which the data should encode. This is 
followed by the data to be encoded.  
  The first character of this data string must be the track's specific Start 
Sentinel (SS) and the last character must be the specific End Sentinel 
(ES).  
  The characters or data in between the SS and ES can include all of the 
valid characters specific to each track.  
  The number of these characters, however, is limited by each track's 
maximum character capacity.  
  When segmenting track data, the appropriate Field Separator (FS) must 
be used. The table below shows the SS, ES, FS and the valid characters 
defined for each track.