HDP8500 Industrial Card Printer/Encoder  User Guide     L001617 rev 1.1 
 
Selecting the Calibrate Laminator tab
  
 
The Calibrate Laminator tab is active when the Laminator is automatically detected or when the 
Laminator is manually checked (as a Printer Feature on the Configuration tab).  
  Calibrate button:  Sends calibrate Laminator command to Printer. Follow the 
instruction on the page for setting up the Printer.   
  Lamination Module must be warm before sending Calibration option.  If not an error will 
occur and will trigger  the laminator to warm up . Retry the calibration again after 
several minutes. 
 
Step 
Procedure 
Option
 
Select the Calibrate Laminator tab. 
a.  Remove the Laminate Cartridge 
b.  Ensure the Laminator Cover is closed. 
c.  Click on the Calibrate button.  
d.  Click on the OK button to close the screen. 
e. 
If successful the printer‟s LCD will reset to ready. 
Option
NOTE: Calibration of the Ribbon, Film, and Lamination may also be 
performed from the DISPLAY ICON.     
 
a.   Remove the Laminate Cartridge 
b.  Ensure the Laminator Cover is closed.  
c.  Select Lam Calibrate option from the Display. 
d. 
If successful the printer‟s LCD will reset to ready.