SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL
eNfusion™ HSD-400 High-speed Data Terminal
TEST AND FAULT ISOLATION
This section provides the information required to determine the operational readiness of the
HSD-400 terminals and to aid service personnel in diagnosing system faults, including the
following sections:
HSD-400 terminals and to aid service personnel in diagnosing system faults, including the
following sections:
•
•
•
•
The operational and diagnostic tests described in this section require using the HSD-400
terminals built-in diagnostic tool referred to as the HSD-400 terminal Maintenance Port Utility
(MPU). This section provides detailed descriptions of the HSD-400 terminal MPU menus,
reports, and basic user instructions. See page 4–2 for maintenance port cabling notes.
terminals built-in diagnostic tool referred to as the HSD-400 terminal Maintenance Port Utility
(MPU). This section provides detailed descriptions of the HSD-400 terminal MPU menus,
reports, and basic user instructions. See page 4–2 for maintenance port cabling notes.
Note: Depending on the version of software installed, the MPU report and menu screens
displayed may differ from those shown as examples in this manual.
1.
Operational and Diagnostic Testing
Usually, terminals require testing for one of the following reasons:
•
To verify the operational readiness of the terminal during and after installation on an
aircraft.
•
To verify that a fault exists and produce system reports for troubleshooting purposes.
•
To verify the operational readiness of repaired LRUs during re-installation on an
aircraft.
This section presents software loading and test and fault isolation procedures for the
HSD-400 terminals. All test and load procedures require the HSD-400 terminal MPU,
which is accessed by connecting to the maintenance port of the terminal.
HSD-400 terminals. All test and load procedures require the HSD-400 terminal MPU,
which is accessed by connecting to the maintenance port of the terminal.
A. Test and Fault Isolation Equipment Requirements
Table 4-1 lists the equipment required to access the HSD-400 terminal MPU and perform
operational and diagnostic testing and software loads on the HSD-400 terminal.
operational and diagnostic testing and software loads on the HSD-400 terminal.
Table 4-2 lists the optional equipment or information that, although not required, may
increase test efficiency or allow for optional diagnostic procedures. Equivalent
substitutions may be used.
increase test efficiency or allow for optional diagnostic procedures. Equivalent
substitutions may be used.
Table 4-1. List of Required Test Equipment
Item
Equipment
Specification
Quantity
Computer Standard VT-100 386 CPU, 20-MHz or
higher
1
VT-100 terminal
emulation program
HyperTerminal©,
ProComm Plus©, or
equivalent
Serial communication
program using an RS-232 port 1