1.2.6
Mounting
the Wireless
Devices
the Wireless
Devices
Do not permanently mount the wireless devices until you have completed the
Placement Tests (see 1.2.7 Enrolling Devices and Setting Up the System on
page 10). Once you have a good location for each of the devices, follow the
mounting instructions on the Installation Instruction sheet for each device. For
WLS904P-433, see Appendix D: WLS904P Wireless Motion Detector Installa-
tion Instructions on page 62. For WLS925L-433, see Appendix C: WLS925L-433
Mini Door/Window Contact Installation Instructions on page 61.
Placement Tests (see 1.2.7 Enrolling Devices and Setting Up the System on
page 10). Once you have a good location for each of the devices, follow the
mounting instructions on the Installation Instruction sheet for each device. For
WLS904P-433, see Appendix D: WLS904P Wireless Motion Detector Installa-
tion Instructions on page 62. For WLS925L-433, see Appendix C: WLS925L-433
Mini Door/Window Contact Installation Instructions on page 61.
1.2.7
Enrolling
Devices and
Setting Up
the System
Devices and
Setting Up
the System
Flash Programming will guide you through the steps needed to set up each zone and
basic system programming. If you need to perform more advanced programming for
your installation, please see Chapter 2: Advanced Programming on page 15.
basic system programming. If you need to perform more advanced programming for
your installation, please see Chapter 2: Advanced Programming on page 15.
To access Flash Programming:
1. Press [✱][8].
2. Enter the Installer’s code. The Installer Code is [5555] at default, but should be
changed to prevent unauthorized access to programming.
3. Press [1] to enter Flash Programming.
4. Follow the audio instructions announced by Flash Programming. Flash Program-
ming will guide you through the following programming areas:
■
Device enrollment
■
Zone label assignment
■
Central station telephone number
■
System account code
■
Placement tests of each wireless device
You can use the Forward (Playback) button to advance to the next section in
Flash Programming, and the Backward (Record) button to return to the previous
section.
Flash Programming, and the Backward (Record) button to return to the previous
section.
5. Be sure to record all the zone serial numbers and your programming choices in
the NT9010 Programming Worksheets.
Here are some notes about system programming done through Flash Programming.
Zone Definitions
When you enter a serial number for a device into the NT9010 Flash Programming,
the unit will analyze the number to determine what kind of device you are enroll-
ing. Based on the type of device, the system will make the following programming
choices:
When you enter a serial number for a device into the NT9010 Flash Programming,
the unit will analyze the number to determine what kind of device you are enroll-
ing. Based on the type of device, the system will make the following programming
choices:
Device Type
Zone Definition
Other Programming
Door/window contact
(2XXXXX, including hard-
wired contacts entered as
200001 and 200002)
(2XXXXX, including hard-
wired contacts entered as
200001 and 200002)
Delay 1 (Type [01])
For hardwired zones (serial
numbers 200001 and
200002), Zone Supervision
disabled (section [804])
numbers 200001 and
200002), Zone Supervision
disabled (section [804])
Motion or glassbreak
detector (3XXXXX)
detector (3XXXXX)
Interior Stay/Away
(Type [05])
(Type [05])
None
Smoke detector
(4XXXXX)
(4XXXXX)
Delayed 24 Hour Fire
(Type [87])
(Type [87])
None
Wireless key (6XXXXX)
None
None