Materials list:
1.  Scul-Com 
® Sensor
2.  Two new Alkaline AAA batteries (customer provided)
Preliminary:
The Scul-Com
® Sensor is designed to be installed on above-ground, indoor storage
tanks equipped with either a Scully MagneLink Twis-Lok
® or Ventalarm® gauge.
To test the gauge, unscrew the sight glass from the oil gauge. Slowly lift the gauge rod
and let it drop. You should hear a light splash. Let the rod come to rest. Gently press
down on the rod. It should slowly return to its original position. If the gauge does not
react in this fashion, replace it with the proper Scully Twis-Lok
® gauge.
If the existing Scully gauge is not factory equipped with a magnet, install a magnet
upgrade kit (P/N 0063) per the instructions packaged with the upgrade kit.  
    Figure 1  Transmitter Mounting Assembly