Seiko Epson Corporation DGE001 Manuale Utente

Pagina di 43
2. SPECIFICATIONS 
 
 
EPSON 
S4E16400/S4E16401 Technical Manual 
(Rev.1.1) 
Pins for Soldering -2 
 
No. Pin 
Name In/Out 
Description 
1 TEST1 
-
Test pin. Leave this pin open. 
2 TEST2 
-
Test pin. Leave this pin open. 
3 TEST3 
-
Test pin. Leave this pin open. 
4 TEST4 
-
Test pin. Leave this pin open. 
5 TEST5 
-
Test pin. Leave this pin open. 
6 TEST6 
-
Test pin. Leave this pin open. 
 
 
2.2.4  
Absolute Maximum Ratings 
 
Item Symbol  Standard  Unit Remarks 
Supply voltage 
V
DD
 
-0.3 to +7.0 
 
Input current 
Iin 
Max. 800 
mA 
 
Input pin voltage 
Vin 
-0.3 to +7.0 
 
Performance assurance 
temperature 
Top 
-10 to +45 
°C 
 
Operating humidity 
Hop 
Max. 90 
%RH 
 
Storage temperature 
Tst 
-20 to +60 
°C 
 
Storage humidity 
Hst 
Max. 90 
%RH 
 
 
[Caution] Using with a condition exceeding the above absolute maximum rating may result in malfunction or 
unrecoverable damage. Moreover, normal function may be achieved temporarily but its reliability 
may be significantly low. 
 
 
2.2.5  
Electrical Characteristics 
 
The following describes the electrical characteristics of the primary circuit module. 
 
Item Symbol 
Conditions  Min. 
Typ. 
Max. 
Unit 
Supply voltage 
V
DD
 
 
5.2 5.4 5.6 
Input current 
Iin 
 
 
 
700 
mA 
Standby power 
Pstb 
Excluding AC adapter 
 
 
50 
mW 
Low input voltage   
detection 
Vlow 
For continuous 5 sec. 
3.8 4.0 4.2 
Transmission frequency 
F1 
During power transmission 
 
121.21 
 
kHz 
Transmission frequency 
F2 
During authentication   
(Approx. 500 msec) 
 129.03  kHz 
Transmission frequency 
F3 
During detection of a foreign 
material (including a metal)   
(Approx. 1 msec) 
 114  
kHz 
 
[Caution] Do not use the product over the range of the power voltage or input current. The authentication 
function and various detection functions may not properly operate and cause a functional failure. 
[Caution] Only the coil unit specified by Epson must be connected for use. When using a coil unit or circuit 
module other than specified, or using a modified coil unit or circuit module, safety and other 
functions may not operate normally. Using such items results nonconformity of technical standards 
related to the radio law.