2. SPECIFICATIONS 
 
 
S4E16400/S4E16401 Technical Manual 
EPSON 
(Rev.1.1) 
Electrical Characteristics of Primary Coil Unit 
 
Item Symbol Condition  Min. 
Typ. 
Max. 
Unit 
Inductance L1c  
 
19.6 
 
uH 
Resistance R2c  
 
203 
 
m
Ω 
 
 
2.2.6  
Functional Description 
 
The following describes the functions of the primary module. 
 
Item Description 
Detection of landing 
Monitors intermittently to check whether the secondary module is placed on the top 
of the primary module. 
Fig. 3 shows the timing of the landing detection. 
Detection removal 
Detects removal of the secondary module from the primary module, and enters 
standby status. 
Authentication Reciprocal 
process of authentication between the primary module and secondary 
module. The process ensures that the power transmission is permitted only between 
the predefined combination. The authentication procedure will be defined 
separately. 
Detection of foreign metal 
objects 
Monitors constantly to check whether any foreign metal object is inserted. If 
detected, the module stops power transmission. However some metals objects may 
not be detected depending on the method of embedding the module into chassis or 
characteristics of the object. Therefore, this function is not assured to detect every 
bit of the foreign objects. After the foreign metal object is removed, the module 
resumes the initial state. 
Detection of foreign metal 
objects 
Detects the temperature of the center of coil, and when it becomes 70 
°C or higher, 
stops the power transmission. Power-on reset is required to resume the 
transmission. 
Installing thermistor between VREF and TDET as shown in the following diagram 
enables you to detect temperature at any position. 
Detected temperature: 60
°C (absolute temperature, recommended component is 
used) 
VREF
TDET
1000pF
RT
External
100KΩ
 
Recommended component   
Murata Manufacturing NCP15WF104F03RC (100K
Ω ±1%/4250K±1%) 
Overvoltage protection 
Stops  power  supply to the subsequent overvoltage protection blocks immediately 
when input voltage exceeds 6.2 
± 0.2V.When the input voltage returns to normal 
level, the module resumes the initial state. 
Detection of low voltage 
Stops  power  transmission  when input voltage drops below 4.0 V during the 
transmission. Power-on reset is required to resume the transmission. 
Detection of low voltage 
Can  display the state of primary module by connecting LED with the LEDA and 
LEDK pins. 
 
State LED 
Standby Off 
During power transmission 
On 
Standby after fully charged 
Off 
When detecting abnormal temperature 
Blinking 
When detecting low voltage 
Blinking