Digital Monitoring Products Inc PC0132 Manuale Utente
9800 Series Keypad Installation Guide
9
Installer Options Menu
Keypad Options and Keypad Diagnostic menus allow installing and service technicians
to configure and test keypad operation.
Access the Installer Options Menu
Access the Options menu through the carousel menu. While in the Option display,
press the Installer Options icon and enter the code 3577 (INST) at the keypad and
press CMD.
The Options menu allows you to set the keypad address, select Supervised or
The Options menu allows you to set the keypad address, select Supervised or
Unsupervised mode, selectively enable the Panic keys, Bypass, Request-to-Exit, and
set entry card options.
Note: All programming options display on all keypad models, however, actual
Note: All programming options display on all keypad models, however, actual
operation for some programming options is restricted to the appropriate model.
Programming Keypad Options
KPD KPD KPD
OPT DIAG RF STOP
OPT DIAG RF STOP
Keypad Options (KPD OPT)
To program keypad options, press KPD OPT.
Default Keypad Message
Enter a custom message of up to 16 characters to appear
on the keypad display top line whenever that line is not
used for any other purpose. Press any Select area to clear
the current message and enter a new custom display.
ARm PAnIc KeyS:
*Pn *em *FI
*Pn *em *FI
Arm Panic Keys
Use this option to configure the Panic Icons. To enable
or disable a Panic Icon, press the icon name: PN (Panic),
EM (Emergency), and FI (Fire). Once the panic icon is
enabled, an asterisk displays next to the description and
the respective Panic icons display for the user. Refer to
the Panic Icon Options section in this document.
nO OF uSeR cODe
DIGITS:
5
Number of User Code Digits
The keypad recognizes user codes from 4 to 10 digits
in length. Press the display to enter the user code digit
length being used by the panel. Default is 5.
When searching the bit string for the user code, the digits
are identified and read from left to right.
All?:
nO yeS
DelAy:
2
Arming/Disarming Wait Time
Select the number of seconds (1-9) the keypad should
wait when an area system displays ALL? NO YES during
arming/disarming or a HOME/SLEEP/AWAY system waits
during arming only. If NO or YES, or HOME, SLEEP, or
AWAY is not manually selected before the delay expires,
the keypad automatically selects the YES or the AWAY
key. Enter zero (0) to disable this feature. The delay also
occurs when any credential is presented for arming the
HOME/SLEEP/AWAY system.
DeFAulT KPD mSG: