Digital Monitoring Products Inc PC0132 User Manual

Page of 22
 
9800 Series Keypad Installation Guide 
9
Installer Options Menu
Keypad Options and Keypad Diagnostic menus allow installing and service technicians 
to configure and test keypad operation.
Access the Installer Options Menu
Access the Options menu through the carousel menu. While in the Option display, 
press the Installer Options icon and enter the code 3577 (INST) at the keypad and 
press CMD.
The Options menu allows you to set the keypad address, select Supervised or 
Unsupervised mode, selectively enable the Panic keys, Bypass, Request-to-Exit, and 
set entry card options.
Note: All programming options display on all keypad models, however, actual 
operation for some programming options is restricted to the appropriate model.
Programming Keypad Options
KPD KPD KPD
OPT DIAG RF    STOP
  Keypad Options (KPD OPT)
To program keypad options, press KPD OPT.
 
Default Keypad Message
Enter a custom message of up to 16 characters to appear 
on the keypad display top line whenever that line is not 
used for any other purpose. Press any Select area to clear 
the current message and enter a new custom display.
ARm PAnIc KeyS:
*Pn *em  *FI
  Arm Panic Keys
Use this option to configure the Panic Icons. To enable 
or disable a Panic Icon, press the icon name: PN (Panic), 
EM (Emergency), and FI (Fire). Once the panic icon is 
enabled, an asterisk displays next to the description and 
the respective Panic icons display for the user. Refer to 
the Panic Icon Options section in this document.
nO OF uSeR cODe 
DIGITS:    
5
  Number of User Code Digits
The keypad recognizes user codes from 4 to 10 digits 
in length. Press the display to enter the user code digit 
length being used by the panel. Default is 5. 
When searching the bit string for the user code, the digits 
are identified and read from left to right.
All?: 
  nO yeS
DelAy:    
2
  Arming/Disarming Wait Time
Select the number of seconds (1-9) the keypad should 
wait when an area system displays ALL? NO YES during 
arming/disarming or a HOME/SLEEP/AWAY system waits 
during arming only. If NO or YES, or HOME, SLEEP, or 
AWAY is not manually selected before the delay expires, 
the keypad automatically selects the YES or the AWAY 
key. Enter zero (0) to disable this feature. The delay also 
occurs when any credential is presented for arming the 
HOME/SLEEP/AWAY system.
DeFAulT KPD mSG: