Honeywell International Inc. 8DL5800RL-2 Manuale Utente
K3790V1 6/07 Rev. A
ADEMCO 5800RL
Wireless Relay Module
INSTALLATION AND SETUP GUIDE
INTRODUCTION
The ADEMCO 5800RL is a Wireless Relay Module that
enables use of remote sounders and/or remote arm/disarm
indicators using two relays activated by wireless signals from
the LYNX control (see Figure 1). The 5800RL can also send
tamper and supervision signals to the LYNX if so
programmed. The 5800RL is compatible with LYNX controls
having software versions 9.0 or higher. Refer to the LYNX
control installation and setup guide for software compatibility
and zone programming information.
enables use of remote sounders and/or remote arm/disarm
indicators using two relays activated by wireless signals from
the LYNX control (see Figure 1). The 5800RL can also send
tamper and supervision signals to the LYNX if so
programmed. The 5800RL is compatible with LYNX controls
having software versions 9.0 or higher. Refer to the LYNX
control installation and setup guide for software compatibility
and zone programming information.
5800RL
RELAY
MODULE
TAMPER AND
SUPERVISION
SIGNALS SENT
TO CONTROL
MODULE'S 2
RELAYS ARE
ACTIVATED BY
SYSTEM
CONDITIONS
AWAY
OFF
STAY
AUX
5800RF-004-V0
Figure 1. Lynx Interface Diagram
MOUNTING LOCATION GUIDELINES
Use the following guidelines when selecting a mounting
location for the 5800RL Relay Module (see Figure 2):
• Mount the 5800RL in a high location for best wireless
reception.
• Do not mount the 5800RL on or near metal objects. This
decreases range and/or blocks wireless transmissions.
• Locate the 5800RL at least 10 feet from any remote
keypad to avoid interference from the microprocessors in
those units.
those units.
• To avoid voltage loss that occurs on long power lines,
mount the external power supply unit in close proximity to
the 5800RL.
the 5800RL.
Mounting, Wiring, and Setup
IMPORTANT: Before permanently mounting the 5800RL,
perform the setup procedure described in the
perform the setup procedure described in the
Setting Up
the 5800RL section.
1. Remove the 5800RL's cover from the base (using a small
flat head screwdriver, insert screwdriver’s tip in slot at top
of the cover and twist).
of the cover and twist).
2. Using the 5800RL base as a template, position in the
desired location and mark the two mounting holes. See
Figure 2 for mounting hole locations.
Figure 2 for mounting hole locations.
3. Attach the 5800RL base using the fasteners supplied.
Screws and plastic anchors are suitable for a typical
installation, but you may use any two fasteners that
secure the base firmly to the mounting surface.
installation, but you may use any two fasteners that
secure the base firmly to the mounting surface.
4. Connect relay and power wiring to the 5800kRL’s
terminals. Refer to Figure 3 for a typical relay application.
The 5800RL can be powered from either an AC transformer
or DC power supply external power source connected to
terminals 7 and 8 (see Figure 3).
Power source ratings and connections are as follows:
or DC power supply external power source connected to
terminals 7 and 8 (see Figure 3).
Power source ratings and connections are as follows:
Type Rating
Connected
to…
Source
Example
AC
9VAC, 15VA
terminals 7 and 8
Ademco 1332
DC 9VDC,
100mA
N7703
terminals 7 and 8
or plugged into
power connector.
or plugged into
power connector.
NOTE: Use of power sources with higher or lower voltages
may result in damage or failure to operate properly. Non-
ADEMCO power supplies may have connectors installed.
Remove these connectors prior to attempting to connect
power supply to 5800RL.
may result in damage or failure to operate properly. Non-
ADEMCO power supplies may have connectors installed.
Remove these connectors prior to attempting to connect
power supply to 5800RL.
TAMPER
SWITCH
2 - NO
3 - COM
4 - NC
5 - NO
6 - COM
7 - AC OR DC (+) IN
1 - NC
8 - AC OR DC ( ) IN
RELAY A
RELAY B
5800RL-001-V1
LED
(RED)
LED
(YELLOW)
LED
(GREEN)
RF INTERFERENCE
LED (RED)
ANTENNA 2
ANTENNA 1
DIP
SWITCH
MOUNTING
HOLE
MOUNTING
HOLE
1 2 3 4 5 6
ON
OFF
OFF
Figure 2. 5800RL Diagram
2 - NO
3 - COM
4 - NC
5 - NO
6 - COM
7 - AC OR DC (+) IN
1 - NC
8 - AC OR DC ( ) IN
RELAY A
RELAY B
5800RL-005-V0
ANTENNA 2
SOUNDER
ANTENNA 1
1 2 3 4 5 6
ON
OFF
OFF
ADEMCO AD12612
AUX PWR SUPPLY
(12 VDC)
AUX PWR SUPPLY
(12 VDC)
AC
IN
+
_
DC
OUT
1361
+
_
RED
BLA
CK
POWER SUPPLY
BACKUP
BATTERY 12VDC
+
PWR SUPPLY
XFMR
16.5VAC
Figure 3. Typical Sounder Wiring Installation
Setting Up the 5800RL
Refer to RELAY and LED Operation section and DIP Switch
(Figure 4) in order to set up the 5800RL as follows:
(Figure 4) in order to set up the 5800RL as follows:
5. Set DIP switches 3-6 (Figure 4) to the appropriate House
ID (1-31). Make sure the House ID set by the DIP
switches matches that entered in the LYNX control.
switches matches that entered in the LYNX control.
6. If module supervision and/or tamper protection is desired,
program the 5800RL’s tamper/supervisory loop (1) as a
zone and enroll its serial number.
zone and enroll its serial number.
Note the following when enrolling:
Zone Type = 5 (trouble by day/alarm by night)
Input Type = 3 (RF)
Loop Number = 1
Input Type = 3 (RF)
Loop Number = 1
PLEASE GO TO THE BOTTOM RIGHT OF PAGE 2