W8665A,E RF RECEIVER MODULE
5
69-1534-1
SETUP
Setting Up W8665A,E to Receive Signals 
from the T8665A Thermostat(s)
The T8665A Thermostat(s) require(s) setup to send 
signals to the W8665 Receiver Module to operate:
 The W8665A Receiver is used for single-zone 
applications.
The W8665E RF Zone™ Panel is used for up to three 
T8665A Thermostats for multi-zone applications.
IMPORTANT
Be sure the thermostat is at least five feet away 
from the W8665 during setup.
Single Zone Applications (1 W8665A/1 T8665A)
1.
Power up the W8665A and install the batteries in 
the T8665A Thermostat. 
2.
Place the W8665A Zone 1 DIP switch to the On 
position.
NOTE:
The W8665A Zone 1 LED will flash.
3.
Press the thermostat Fan On key:
a. The receiver accepts the message and stores 
the identity.
b. The zone 1 LED stops flashing.
c. The thermostat is now set to send signals to 
the W866A Receiver.
NOTE:
The word, On, and a fan blade 
 appear in the 
thermostat display to indicate the thermostat is 
calling for the fan to turn on.
d. Use Fan key to turn off fan.
4.
Set System and Fan keys to the desired locations.
NOTE:
At any time, if you want to stop the thermostat 
from sending signals to the W8665 Receiver, 
turn the DIP switch to Off. Then repeat steps 1-
3 to set up the thermostat to send signals to the 
W8665 Receiver.
Multizone Applications (1 W8665E/Up to 3 
T8665A)
1.
Power up the W8665 and install the batteries in the 
T8665 Thermostats.
2.
Set the thermostats so no zones are calling for sys-
tem or fan.
3.
Set up each zone separately to ensure that a 
unique address is used for each zone.
4.
Place the zone 1 DIP switch on the W8665E 
Receiver to the On position.
NOTE:
The W8665E zone 1 LED will flash.
5.
Press the thermostat Fan On key:
a. The receiver accepts the message and stores 
the zone identity.
b. The zone 1 LED stops flashing.
c. The thermostat is now set to send signals to 
the W8665E Receiver.
NOTE:
The word, On, and a fan blade 
 appear in the 
thermostat display to indicate the thermostat is 
calling for the fan to turn on. 
d. Use Fan key to turn off fan.
NOTE:
At any time, if you want to stop the thermostat 
from sending signals to the W8665 Receiver, 
turn the DIP switch to Off. Then repeat steps 4 
and 5 to set up the thermostat to send signals to 
the W8665 Receiver.
6.
Repeat steps 4 and 5 for zones two and three.
7.
Set System and Fan keys to desired locations.
8.
Attach the zone number sticker, included with the 
thermostat, onto the thermostat case on the inside 
of the thermostat cover. See Fig. 5.
Fig. 5. Zone number stickers for inside of thermostat 
cover.
OPERATION
W8665A Sequence of Operation
On a call for heating or cooling, the thermostat sends a 
signal to the W8665A to bring on the heating or cooling 
until the call is satisfied. The Comm LED flashes when 
the W8665A receives a signal from the thermostat to turn 
on the system or approximately every ten minutes as a 
status update. On a call for heating, cooling or fan, the 
zone LED lights red.
W8665E Sequence of Operation
On a call for heating or cooling from any zone, the 
thermostat sends a signal to the W8665E to bring on the 
heating or cooling in that zone until the call is satisfied. 
The Comm LED flashes when the W8665E receives a 
signal from the thermostat in any zone to turn on the 
system or approximately every ten minutes as a status 
update. On a call for heating, cooling or fan, the zone 
LED lights red.
W8665E Single and Multi-Stage 
Operation
The first stage is energized by the thermostat. 
To control multistage conventional and heat pump 
systems, the W8665 must be wired to a zone control 
panel that is able to control multiple stages of heat and/or 
cool (such as the TZ-3 TotalZone™ Zone Control Panel). 
The zone panel (not the RF panel) controls these stages 
based on the number of zones calling or with a timer. See 
the Zone Control Panel Instructions for more details on 
how to control up to three stages of heat and two stages 
of cool.