Honeywell International Inc. 8DL5816AP Manuale Utente

Pagina di 2
 
N6482-4V1  4/05  Rev. A
ADEMCO 5816AP
 Door/Window Transmitter
INSTALLATION AND SETUP GUIDE 
 
 
CASE
HOLDING
POSTS (2)
PLATE
MOUNTING
HOLES (2)
CONCEALED
WIRING
ENTRY HOLE
CASE
LOCKING
TAB
MAGNET ALIGNMENT STRIP
5816-002-V0  
Diagram 1.  Mounting Plate 
+
COVER PRY-OFF POINT 
ANTENNA
HOLES "A" (2)
(SEE TEXT)
LOCKING TAB
RELEASE
 WINDOW
BATTERY
REED
SWITCH
(INPUT 2)
COVER
TAMPER
SWITCH
COVER
HOLDING
HOOKS (2)
A
BREAKOUT FOR
SURFACE WIRING
SLOT FOR CONCEALED
WIRING ACCESS
ALIGN MAGNET
WITH MARKS ON
CASE AND GUIDE
ON MTG. PLATE 
MAGNET
(OBTAIN
SEPARATELY)
LOOP
TERMINALS
(INPUT 1)
A
NOTE
5816
HAS 2
UNIQUE
ZONES
1/2” MAX. 
5816-001-V0
 
 
Diagram 2.  Transmitter, Cover Removed 
 
 
GENERAL INFORMATION 
The 5816AP is a Door/Window Transmitter 
intended for use in systems that support 5800AP 
wireless devices.  It has its own unique serial 
number permanently assigned during 
manufacture. You must “enroll” the transmitter 
serial number in the control prior to its usage in 
the system. Refer to the control unit’s installation 
instructions for further details.  
Note:  During 
programming of the control unit, 5816AP 
transmitters shall be defined as the Input Type 
“RF” (i.e., supervised RF). 
 
The 5816AP has 
two unique zones; the first is for 
a wired closed circuit contact loop and the 
second 
for its built-in reed switch (used in conjunction with 
a magnet as described below). Either or both 
zones may be used. 
 
A built-in cover tamper switch is activated when 
the cover is removed. 
 
INSTALLATION 
Mounting 
For proper orientation of the unit in relation to the 
mounting plate, loop wiring, and/or magnet, read 
all of this section before installing the unit. 
 
The description that follows assumes that the unit 
will be mounted as shown in the diagrams, with 
the magnet (if used) located to the unit’s right. The 
unit may, however, be installed in 
any direction, 
as long as the relationship of the unit to its 
mounting plate and (if used) magnet is 
maintained. 
 
Although two holes are provided in the unit that 
would permit mounting directly to a surface (holes 
‘A’ in Diagram 2) it is recommended that the 
mounting plate be used, for ease in removing the 
unit for servicing should it become necessary. 
 
Before mounting the transmitter permanently, 
conduct Go/No Go tests (see control’s 
instructions) to verify adequate signal strength 
and reorient or relocate the transmitter if 
necessary. 
1. 
Remove the transmitter’s cover by inserting 
the flat blade of a small screwdriver into the 
pry-off slot at the end of the unit farthest from 
the cover’s decorative ribs, and twisting the 
blade. 
2. 
Disengage the supplied mounting plate 
from the unit
 by inserting the blade of a small 
screwdriver into the locking tab release 
window (see Diagram 2) and pressing it 
against the locking tab (see Diagram 1) while 
sliding the plate downward along the case 
back. 
3. 
If a wired contact loop is to be used with 
concealed wiring, feed the wires through the 
concealed wiring entry hole at one corner of 
the mounting plate.  
For 
surface wiring entry, a thin “breakout” 
area is provided in the case wall. Wiring can 
be run through this “breakout” in the case 
when attaching the case in step 5. 
4. 
Install the mounting plate, with its case 
holding posts pointing up (in this example), in 
the location selected as described in the 
control unit’s installation instructions. Use the 
flat head screws supplied.
 
5. 
Attach the case back to the mounting plate 
by sliding the keyhole slots in the case back 
down onto the mounting plate’s case holding 
posts. The locking tab will click as the case 
back locks in place.
 
6. 
If the unit’s reed switch is to be used, a No. 
5799 Magnet (obtain separately) shall be 
mounted adjacent to the alignment marks on 
the case and the mounting plate’s alignment 
strip (see Diagram 2).