Honeywell International Inc. 8DL5817CB-2 Manuale Utente

Pagina di 2
K5623V2  10/07  Rev. A (Preliminary) 
 
LIMITED WARRANTY 
 
Honeywell International Inc., acting through its Security & Custom Electronics business ("Seller"), 2 
Corporate Center Drive, Melville, NY, 11747, warrants its product(s) to be in conformance with its own 
plans and specifications and to be free from defects in materials and workmanship under normal use and 
service for 24 months from the date stamp control on the product(s) or, for product(s) not having a 
manufacturer’s date stamp, for 12 months from date of original purchase unless the installation 
instructions or catalog sets forth a shorter period, in which case the shorter period shall apply. Seller's 
obligation shall be limited to repairing or replacing, at its option, free of charge for materials or labor, 
any product(s) which is proved not in compliance with Seller's specifications or proves defective in 
materials or workmanship under normal use and service. Seller shall have no obligation under this 
Limited Warranty or otherwise if the product(s) is altered or improperly repaired or serviced by anyone 
other than Honeywell factory service. Connection of any device(s) to a communicating bus of a Honeywell 
security system (e.g., keypad bus, polling loop) other than those manufactured or approved by Honeywell 
shall void this warranty.  For warranty service, return product(s) transportation prepaid, to your local 
authorized Honeywell representative. 
THERE ARE NO WARRANTIES, EXPRESS OR IMPLIED, OF MERCHANTABILITY, OR FITNESS FOR A 
PARTICULAR PURPOSE OR OTHERWISE, WHICH EXTEND BEYOND THE DESCRIPTION ON THE FACE 
HEREOF. IN NO CASE SHALL SELLER BE LIABLE TO ANYONE FOR ANY CONSEQUENTIAL OR 
INCIDENTAL DAMAGES FOR BREACH OF THIS OR ANY OTHER WARRANTY, EXPRESS OR IMPLIED, OR 
UPON ANY OTHER BASIS OF LIABILITY WHATSOEVER, EVEN IF THE LOSS OR DAMAGE IS CAUSED BY 
THE SELLER'S OWN NEGLIGENCE OR FAULT. 
Seller does not represent that the product(s) it sells may not be compromised or circumvented; that the 
product(s) will prevent any personal injury or property loss by burglary, robbery, fire or otherwise; or 
that the product(s) will in all cases provide adequate warning or protection. Customer understands that a 
properly installed and maintained alarm system may only reduce the risk of a burglary, robbery, fire, or 
other events occurring without providing an alarm, but it is not insurance or a guarantee that such will 
not occur or that there will be no personal injury or property loss as a result. CONSEQUENTLY, 
SELLER SHALL HAVE NO LIABILITY FOR ANY PERSONAL INJURY, PROPERTY DAMAGE OR 
OTHER LOSS BASED ON A CLAIM THAT THE PRODUCT(S) FAILED TO GIVE WARNING. 
HOWEVER,
 
IF
 
SELLER
 
IS
 
HELD
 
LIABLE,
 
WHETHER
 
DIRECTLY
 
OR
 
INDIRECTLY,
 
FOR
 
ANY
 
LOSS
 
OR
 
DAMAGE
 
ARISING
 
UNDER
 
THIS
 
LIMITED
 
WARRANTY
 
OR
 
OTHERWISE,
 
REGARDLESS
 
OF
 
CAUSE
 
OR
 
ORIGIN,
 
SELLER'S
 
MAXIMUM
 
LIABILITY
 
SHALL
 
NOT
 
IN
 
ANY
 
CASE
 
EXCEED
 
THE
 
PURCHASE
 
PRICE
 
OF
 
THE
 
PRODUCT(S),
 
WHICH
 
SHALL
 
BE
 
THE
 
COMPLETE
 
AND
 
EXCLUSIVE
 
REMEDY
 
AGAINST
 
SELLER. 
This warranty replaces any previous warranties and is the only warranty made by Seller on this 
product(s). No increase or alteration, written or verbal, of the obligations of this Limited Warranty is 
authorized. 
 
This device complies with Part 15 of FCC rules and RSS 210 of IC. Operation is subject to the 
following two conditions: (1) this device may not cause harmful interference. (2) this device must 
accept any interference received, including interference that may cause undesired operation. 
 
Note: The user shall not make any changes or modifications to the equipment unless authorized by the 
Installation and Setup Guide or User Guide. Unauthorized changes or modifications could void the user's 
authority to operate the equipment.
 
 
 
UL 
For dry, indoor use only.  Do not install in air-handling spaces.
 
 
 
 
 
 
 
 
 
 
 
 
 
 
ÊK5623V2PŠ 
2 Corporate Center Drive, Suite 100
P.O. Box 9040
Melville, NY 11747
Copyright © 2007 Honeywell International Inc.
www.security.honeywell.com
 
 
 
 Preliminary K5623V2  10/07  Rev. A
ADEMCO 5817CB
WIRELESS COMMERCIAL/ 
HOUSEHOLD TRANSMITTER
INSTALLATION AND SETUP GUIDE 
GENERAL INFORMATION 
The 5817CB is a universal contact-monitoring transmitter that can be used with household and 
commercial fire and burglary-initiating devices such as door/window contacts, motion and glassbreak 
detectors, sprinkler water flow switches, tamper switches, post indicator valves, manual pull stations, 
and remote duct detectors. Upon activation, it emits an RF signal to a control panel that sends a burglary 
or fire alarm to a central station. The 5817CB has three unique input loops (zones). The first loop 
(primary loop) 
is supervised and typically used for high-priority alarm reporting such as commercial fire 
or burglary. It requires a 470K ohm end-of-line resistor to be placed across the sensor. The second loop is 
the built-in, normally closed reed switch (used in conjunction with a magnet, as described below). The 
third loop is another normally closed household burglary loop. All three loops may be used. A fourth 
(automatically enrolled) loop contains two tamper switches to protect the 5817CB transmitter. A built-in 
cover tamper switch is activated when the cover is removed. A unit tamper switch is activated if the unit 
is separated from its mounting plate.  
PROGRAMMING 
The 5817CB has its own unique serial number permanently assigned during manufacture. You must 
"enroll" this transmitter serial number in the control panel at some point prior to its usage in the alarm 
system. Refer to the control panel's installation instructions for specific programming procedure. Note: 
During programming of the control panel, program the 5817CB transmitter as Input Type "RF" (i.e., 
supervised RF) (mandatory for UL installations). 
MOUNTING 
For proper orientation of the unit in relation to its wall mounting plate and the loop wiring, read all of 
this section before installing the unit. Signal strength may vary from location to location. Before mounting 
the transmitter permanently, conduct Go/No Go tests (see control's instructions) to verify adequate signal 
strength from this location. 
When a satisfactory location is found, make note of the position of the unit 
on the wall
,  
remove the battery and proceed with installation. The following mounting instructions 
assume that the unit will be mounted as shown in the Figures. The unit may, however, be installed in 
any direction, as long as the relationship of the unit to its mounting plate or tamper switch hold-down (if 
used), is maintained. 
The 5817CB is supplied with a tamper switch hold-down tab (connected to the mounting plate as shown in 
Figure 1), for use when the wall mounting plate is not needed. Remove the tab with diagonal cutting 
pliers.
 
The mounting plate, installed as described below, enables easy removal of the unit for servicing, should it 
become necessary. 
1.  Remove the transmitter's cover by inserting the flat blade of a small screwdriver into the pry-off 
slot at the bottom end of the unit on the right side closest to the cover's decorative ribs and twisting.  
2.  Disengage the supplied mounting plate from the unit by inserting the blade of a small 
screwdriver into the mounting plate release hole (see Figure 3) and pushing the locking tab out (see 
Figure 1). Slide the mounting plate downward along the case back. Note: For this application, the 
alignment guide strip along one edge of the mounting plate serves no function and may be broken 
away, if desired. 
3.  If concealed wiring is to be used, feed the wires through the concealed wiring entry hole at one 
corner of the mounting plate (and/or case back).  Surface wiring is discussed in Step 5 below). 
4.  Install the mounting plate, with its case-holding posts pointing up, in the location determined. 
Use two flat head dry-wall screws. Note: To ensure proper operation of the unit's back tamper (when 
it is separated from the mounting plate), the screws must be anchored to a wall stud or other solid 
wood material.  If the mounting plate will not be used, make note of the location of the tamper 
switch hold-down as shown in Fig. 1 for the proper placing of the hold-down tab in Fig. 2. 
5. If 
surface wiring is to be used, remove the knockout slot in the case back (located across from loop 
3 terminal block). Surface wiring should enter through this knocked out space provided. Do not 
connect the wiring to the terminal block(s) yet. 
 
FCC STATEMENTS