Honeywell International Inc. 8DL5817CB-2 Manuale Utente
- 2 -
- 3 -
6. Attach the case back to the mounting plate by sliding the keyhole slots in the case back down onto
the mounting plate's holding posts. The locking tab will click as the case back locks in place. To
disengage the unit from an installed mounting plate, insert a small screwdriver into the
mounting plate release hole, push down to retract the locking tab, and push upward on the unit to
disengage from posts. If not using the mounting plate, it is necessary to remove the PC board
from the case back. Slide a small flat bladed screwdriver between the case back and PC board near
the board hold-down clip and carefully pry the board out.
disengage the unit from an installed mounting plate, insert a small screwdriver into the
mounting plate release hole, push down to retract the locking tab, and push upward on the unit to
disengage from posts. If not using the mounting plate, it is necessary to remove the PC board
from the case back. Slide a small flat bladed screwdriver between the case back and PC board near
the board hold-down clip and carefully pry the board out.
7. In the area that was previously marked for the location of the mounting plate, (step 4), install the
hold-down tab with a 5/8” flat head dry-wall screw. The tab must be aligned with the corresponding
slot in the case back as shown in Figure 2. The tab as well as the case back must be anchored to a
wall stud or other solid wood material.
slot in the case back as shown in Figure 2. The tab as well as the case back must be anchored to a
wall stud or other solid wood material.
8. To reinstall the PC board into the case back, position the board onto the two retaining studs on one
side of the case back and snap the board into place. The hold-down tab must mate with the
corresponding cutout in the case back after case back is installed.
corresponding cutout in the case back after case back is installed.
9. Reverse the procedure of the first three steps to complete reassembly of the unit.
10. Set the DIP switch (after the control panel has enrolled the transmitter's input IDs) for the desired
primary loop characteristics, as described in the table below.
PRIMARY LOOP OPTIONS TABLE
DIP SWITCH POSITION
SWITCH
SETTING
1 2
3
4
ON
REPEATING TRANSMISSION
(every 4 sec.)
UPON PRIMARY LOOP FAULT
Use for high priority
alarm, such as fire.
OFF
SINGLE TRANSMISSION
PER PRIMARY LOOP CHANGE-OF-
STATE
SWITCH
MUST
ALWAYS BE
IN THE
ON
POSITION
SWITCH
MUST
ALWAYS
BE
IN THE
ON
POSITION
SWITCH
MUST
ALWAYS BE
IN THE
OFF
POSITION
Notes:
a. In order for the control panel to enroll the transmitter, the DIP switches must be
set to OFF – ON – ON – OFF (see Figure 3).
b. The Auxiliary loops are not affected by the DIP switch settings.
UL REQUIREMENT
1. If using one of the panel revisions shown in the following table, and programming the 5817CB as an
Entry/Exit zone, you must enroll the tamper loop (loop 4) as a separate zone, programmed for 24-
hour response (e.g., Zone type 5
hour response (e.g., Zone type 5
Trouble-by-day/Alarm-by-night).
Model #
Rev.
EPROM P/N
FA1600C 8
(WAVIS150FA-18)
Vista-32FB 3 (WAVIS32FB-13)
Vista-128FB 4 (WAVIS128FB-14)
Vista-128B 3 (WAVIS128B-13)
2. For UL Commercial Burglary installations, this transmitter must be used in conjunction with the
5881ENHC RF Receiver.
WIRING CONNECTIONS
Connect the loop wiring to the unit's terminals before installing the battery (see Figure 3).
Notes:
Notes:
a. Primary loop 1 is a supervised loop and must have an end-of-line (EOL) resistor (470K
ohms, supplied) placed across the last sensor. Additionally, for Primary loop 1, a contact
device may not be installed more than 20 feet from the transmitter.
device may not be installed more than 20 feet from the transmitter.
b. If loop 2 is not going to be used, the magnet is not necessary.
c. If loop 3 is not going to be used, no connection is needed across its terminals. For UL
household burglary and fire installations, the loop 3 contact device (if used) may not be
more than 3 feet from the transmitter.
more than 3 feet from the transmitter.
BATTERY INSTALLATION/REPLACEMENT
1. Remove the transmitter's cover as described in Mounting Step 1.
1. Remove the transmitter's cover as described in Mounting Step 1.
2. Observe correct polarity and insert the battery provided into the battery holder (see
Figure 3). Take care not to bend the antenna.
Note: Replace
battery
only with: Duracell DL123A, Panasonic CR123A, Ademco 466 or Varta
CR123A.
!
Risk of fire, explosion, and burns. Do not recharge, disassemble, heat above 212°F
(100°C), or incinerate. Dispose of used batteries promptly. Keep away from children.
(100°C), or incinerate. Dispose of used batteries promptly. Keep away from children.
3.
To replace the cover, engage the hooks along the top edge and snap shut.
SPECIFICATIONS
Dimensions:
Dimensions:
1-9/16"W x 3-1/2"H x 1-3/16"D (40mm x 89mm x 30mm)
Battery:
3V Lithium (see BATTERY INSTALLATION/REPLACEMENT).
UL Listings:
Commercial Fire…….UL864 Household
Burg……..UL1023
Household Fire………UL985 Commercial
Burg……UL365, UL609, UL1076, UL1610
This is a CLASS B DEVICE
TESTING
Regular maintenance and inspection (at least annually) by the installer and frequent testing by the user
are vital to continuous satisfactory operation of any alarm system. For testing procedures refer to the
User Guide or Installation and Setup Guide for the system control panel.
are vital to continuous satisfactory operation of any alarm system. For testing procedures refer to the
User Guide or Installation and Setup Guide for the system control panel.
The installer should assume the responsibility of developing and offering a regular maintenance program
to the user, as well as acquainting the user with the proper operation and limitations of the alarm system
and its component parts. Recommendations must be included for a specific program of frequent testing
(at least weekly) to insure the system's operation at all times.
to the user, as well as acquainting the user with the proper operation and limitations of the alarm system
and its component parts. Recommendations must be included for a specific program of frequent testing
(at least weekly) to insure the system's operation at all times.
FOR DETAILS ON LIMITATIONS OF THE ENTIRE ALARM SYSTEM, REFER TO THE
CONTROL PANEL'S INSTALLATION AND SETUP GUIDE FOR THE RECEIVER/CONTROL
WITH WHICH THIS DEVICE IS USED.
CONTROL PANEL'S INSTALLATION AND SETUP GUIDE FOR THE RECEIVER/CONTROL
WITH WHICH THIS DEVICE IS USED.
5817CB-001-V1
MOUNTING
PLATE
HOLE
CASE
HOLDING
POSTS
HOLDING
POSTS
CONCEALED
WIRING
ENTRY
HOLE
MOUNTING
PLATE HOLE
PLATE HOLE
TAMPER SWITCH
HOLD DOWN
LOCKING
TAB
TAB
HOLD-DOWN
TAB
TAB
Figure 1. Mounting Plate
5817CB-001-V0
TAMPER SWITCH
HOLD-DOWN TAB
HOLD-DOWN TAB
CASE BACK
CONCEALED
WIRING
ENTRY HOLE
MOUNTING
HOLES (2)
HOLES (2)
INSTALL
IN LINE WITH
CUT-OUT
IN CASE BACK
Figure 2. Case Back
NOTE: For UL commercial
and household fire
installations, only one initiating
device may be connected to
this transmitter. For UL
commercial burglary
installations, multiple initiating
devices may be used as long
as the devices all serve the
same function, such as
door/window contacts, motion
or glassbreak detectors. All
initiating devices must be
located within the same room.
and household fire
installations, only one initiating
device may be connected to
this transmitter. For UL
commercial burglary
installations, multiple initiating
devices may be used as long
as the devices all serve the
same function, such as
door/window contacts, motion
or glassbreak detectors. All
initiating devices must be
located within the same room.
+
–
BATTERY
5817CB-002-V1
DIP
SWITCH
COVER
HOLDING
SLOTS (2)
ANTENNA
COVER
TAMPER
SWITCH
COVER
PRY-OFF
POINT
MOUNTING
PLATE
RELEASE
PLATE
RELEASE
1/2"
MAX.
N.O.
CONTACT
DEVICE
N.C.
CONTACT
DEVICE
LOOP 3
TERMINALS
(AUX)
ALIGN MAGNET
WITH MARKS ON
CASE (2 PLACES)
WITH MARKS ON
CASE (2 PLACES)
MAGNET
(OBTAIN
SEPARATELY)
(OBTAIN
SEPARATELY)
LOOP 2
REED SWITCH
(AUX)
REED SWITCH
(AUX)
PRIMARY
LOOP 1
TERMINALS
LOOP 1
TERMINALS
DIP SWITCH FOR PRIMARY LOOP OPTIONS
(SEE SETTINGS TABLE)
SHOWN SET FOR: 1. SINGLE TRANSMISSION
NOTE: SW2 MUST BE ON
ON
OFF
ON
1 2 3 4
WHITE AREA
INDICATES
SWITCH HANDLE
INDICATES
SWITCH HANDLE
THE DIP SWITCHES MUST BE
SET AS SHOWN DURING
ENROLLMENT BY THE CONTROL
SET AS SHOWN DURING
ENROLLMENT BY THE CONTROL
SLOT FOR
CONCEALED
WIRING ACCESS
SW3 MUST BE ON
SW4 MUST BE OFF
SW4 MUST BE OFF
EOLR
470K ohms
Figure 3. 5817CB Transmitter, Top Cover Removed