GENERAL INFORMATION 
The 5818MNL Recessed Door Transmitter is a single-
zone, reed switch magnetic contact sensor that 
provides concealed protection for a door. It is intended 
for use only with alarm systems that support 5800 
series devices. 
The transmitter is powered by one AAA Lithium (or 
alkaline) battery that is easily replaced when a low 
battery condition is indicated by the control panel. 
PROGRAMMING  
Each 5818MNL has its own unique identification code 
(serial number) permanently assigned during 
manufacture. 
You must “enroll” the transmitter’s serial number in the 
control panel before it will operate in the system.  
Note:  
During programming of the control panel, 
5818MNL transmitters must be enrolled as Input Type 
3 (Supervised RF), Loop 1 (
mandatory for UL 
installations). 
INSTALLATION  
Note: Do not use on metal frame doors. 
Mounting 
Before selecting the mounting location, please read 
the following: 
•  The preferred direction of mounting is vertical, 
although the 5818MNL may be mounted in 
any 
direction if satisfactory reception of its 
transmissions is obtained.  
••••  A physical barrier (e.g., a molding strip on the 
door frame) should be present to protect against 
defeat of the contact from outside the premises. 
••••  Make sure that no more than 1/2” gap exists 
between the faces of the transmitter and magnet 
cases when they are installed and set. 
••••  Once installed, an alarm signal must be 
obtained before a separation of 2” is reached 
as the door is opened. 
 
 
 
TRANSMITTER
CASE
ANTENNA
END CAP
REED
SWITCH
PC BOARD
5818MN-001-V0
 
 
Figure 2: Battery/Transmitter Assembly 
 
1.  Select a location for the transmitter on the door 
frame (never on the hinged edge). 
Caution: Do not 
install in the door. 
2.  Select the location for the magnet on the door, 
directly opposite the transmitter location.  
3.  Tape the transmitter and magnet in their 
approximate locations (with battery installed and 
unit together as described in the BATTERY 
INSTALLATION / REPLACEMENT section below 
and conduct Go/No Go tests (refer to control 
panel’s instructions) to verify adequate signal 
strength. Reorient or relocate transmitter if 
necessary.
 
4.  Mark the selected locations. 
 
5. Drill holes at the locations marked. The transmitter 
will require a 3/4” diameter hole in the edge of the 
frame, at least 3” deep. The magnet will require a 
3/8” diameter hole in the edge of the door at least 
1/2” deep.
 
6. Insert the transmitter and magnet cases into 
their respective holes,  so that their ends are flush 
with the surface.
 
• DO NOT hammer in place with hard blows. If 
necessary, tap 
gently with a rubber mallet or 
wood block. 
•  The transmitter case may be secured by two #4 
flat head, self-tapping screws via the holes in its 
mounting flanges, or the flanges can be 
snapped off by scoring around them first with a 
sharp knife. 
•  If necessary, either case may be secured with a 
suitable adhesive. 
 
NOTE:
 A closure plug is supplied to cover an empty 
transmitter hole if it becomes necessary to relocate 