GENERAL INFORMATION 
The 5842 Wireless Dialer is a combination Central Station 
dialer and RF transceiver. It receives and acknowledges RF 
messages from the control’s transceiver. In response, it 
sends reports to the central station via the dialer. The 5842 
also sends acknowledgements, supervisory and tamper RF 
transmissions to the control.  
 
DIALER FEATURES 
•  ADEMCO Contact ID® central station reporting format. 
•  Reports low battery conditions to control panel. 
•  Front cover tamper switch. 
 
The LEDs and their functions are described below: 
LED Function 
Green 
Lights continuously and flickers during RF activity. 
Yellow 
Flashes once each time the 5842 sends an 
acknowledge message to the control. Stays on while 
the dialer is using the telephone line. 
Red 
Lights to indicate no setup information has been 
received, or setup information is incomplete. Once 
setup information is received the LED will go off. 
 
 
RED
YEL
GRN
MOUNTING
HOLES
(4)
ANTENNAS
(INSERT IN
RIGHT-HAND
TERMINALS)
BREAKOUT
WIRING
OPENING
TAMPER
SWITCH
RJ31X
TELEPHONE
JACK
WIRING
OPENING
5842-001-V0
TELEPHONE IN
TELEPHONE OUT
RJ11
TELEPHONE
JACK
BATTERY
BATTERY
 
 
Figure 1 - 5842 Wireless Dialer (cover removed) 
 
OPERATION 
The 5842 dialer is triggered by an RF message that contains a command, (i.e. a dialer report message or a line seize and clear 
command). It processes the command and remains active for a short time after it has received and acknowledged the last RF 
message from the control panel. The 5842 then reverts to Low current standby mode. The Wireless Dialer is normally in a low 
current standby mode, which maximizes battery life. At specific intervals the unit’s RF receiver is switched on, and listens for a 
“Time Sync” message from the control panel. If the “Time Sync” message is not received within a specified time the 5842 switches 
to an active receiving state. If the 5842 still does not receive a message it transmits a time sync fault to the control panel. Normal 
operation resumes after the control panel logs the event and transmits a “Time Sync Fault Restore” message. Failure to receive a 
kiss-off signal from the central station is reported to the control panel. Dialer reports are sent to the central station using 
ADEMCO Contact ID® format only.  
 
 
PROGRAMMING AND INSTALLING THE 5842 WIRELESS DIALER 
Refer to the following procedure and the Installation and Setup Guide for the Control Panel being installed to program and 