Honeywell International Inc. 8DL5882-4 Manuale Utente

Pagina di 8
 
 
N7635-3V3  1/01
 
5881EN Series 
RF Receiver 
INSTALLATION AND SETUP GUIDE
 
INTRODUCTION 
The 5881EN series of RF receivers is designed for use with 
control panels that support an RF receiver connection via 
the keypad terminals
. The receiver recognizes alarm, status, 
and keypad control messages from wireless transmitters 
operating at 345MHz.  
One or two individually identified receivers can be 
employed, depending on the control used. Connection of 
multiple receivers to a control can provide redundant 
coverage or extend coverage in large areas. 
These receivers feature a Spatial Diversity System that 
virtually eliminates the possibility of "nulls" and "dead 
spots" within the coverage area. The 5881EN series of 
receivers use ADEMCO’s new Signal-Sentry™ technology, 
and can be used in commercial fire installations. 
Additionally, the 5881ENHC receiver contains front and 
back tamper that permits its use in commercial burglary 
installations. 
UL
 
  In commercial fire applications, the receiver can 
only be used with control panels that are approved 
for use in Commercial Fire Installations. When the 
5881EN is used in commercial fire applications, 
DIP switch 5 must be in the ON position. 
 
In commercial burglary applications, the 
5881ENHC can only be used with control panels 
that are approved for use in Commercial Burglary 
Installations. 
  In commercial fire applications, a keypad must be 
connected to Keypad Port 2 in the control. The 
keypad must be mounted on the control or within 3 
feet of the control with the wiring encased in 
conduit.
 
Each receiver supports the number of zones shown below. 
5881ENL
 
Up to 8 zones
 
5881ENM
 
Up to 16 zones
 
5881ENH
 
*See below
 
5881ENHC
 
*See below
 
* The number of zones that the 5881ENH 
receiver can support depends on the 
control with which it is used. See the 
control panel’s instructions for specific 
details. 
If a receiver is connected to a system in which more than 
the permitted number of wireless zones have been 
programmed, a "SET UP ERROR" message (on alpha 
keypads) or an "E4 or “E8”" message (on fixed-word 
keypads) will be displayed on the system's keypad, and none 
of the zones will be protected. 
The instruction manual that accompanies the control 
includes recommendations regarding receiver and 
transmitter locations, the types of wireless zones that can 
be programmed (e.g., ENTRY/EXIT, PERIMETER, 
INTERIOR, etc.) and the procedure for programming the 
receivers. 
These receivers should not be installed in an area subject to 
environmental extremes of below freezing (such as an 
unheated warehouse) or extremely high temperatures (such 
as an attic). 
INSTALLATION 
With some controls, a receiver may be mounted directly 
inside the control's cabinet (receiver circuit board only, 
without its plastic housing) instead of remotely (in its own 
housing). In both cases, avoid mounting the receiver 
antennas against a metal surface. 
NOTE: You may only mount the 5881ENHC its own plastic 
housing. If you attempt to mount the 5881ENHC in the 
control’s cabinet, the receiver constantly reports a tamper 
condition. 
1.  Remove the receiver's cover by inserting and twisting 
a screwdriver blade in the slot at the center of the cover's 
lower edge. 
2. If the receiver is to be mounted within the 
control's cabinet (refer to Figure 1): 
a.  Remove the receiver's circuit board from its base by 
bending back the two flexible plastic tabs that hold 
the board's lower edge. 
b. In the control's cabinet, unfasten and move the 
control circuit board downward (if already installed). 
c.  Hang two mounting clips (provided with the receiver) 
on the raised cabinet tabs, as shown in Detail B of 
Figure 1. 
d.  Insert the top of the receiver board between the rows 
of slots at the top of the cabinet, as shown in Detail A. 
e. Position the base of the receiver board onto the 
mounting clips and secure to the cabinet with the 
supplied screws. See Detail B. 
f.  Hang two mounting clips (supplied with the control 
board), on the raised cabinet tabs as shown in Detail 
C in Figure 1. 
g.  Insert the top of the control board into the slots of the 
mounting clips secured in step e above. 
h.  Position the lower end of the control board into place 
on the mounting clips and secure both to the cabinet 
with the two supplied screws.  
i. Insert both grounding lugs (supplied with the 
receiver) through the top of the cabinet into the left-
hand
 terminals of the antenna blocks (located on the 
upper edge of the receiver board), and secure them to 
the cabinet with the screws provided, as shown in 
Detail D.