Honeywell International Inc. 8DL6160VPADT Manuale Utente

Pagina di 4
 
PREK14804  6/07  Rev. A 
    
 
6160VPADT
6160VPADT
6160VPADT
6160VPADT  
Remote Touchpad with Prox Reader
INSTALLATION and SETUP GUIDE 
 
 
GENERAL INFORMATION 
The 6160VPADT is an addressable remote Touchpad 
designed for use with ADT control panels.  This Touchpad 
provides the following features:   
•  Backlit Display 
•  Programmable Function Keys 
•  Built-in Sounder 
•  Arm/Disarm via Prox Tag 
•  Voice Chime 
•  Voice Status 
•  Message Center 
 
Notes:  
•  When used with the Safewatch Pro/Security Manager 
3000 control panels, address 16 must be assigned to the 
first Touchpad.  Additional Touchpads must be assigned to 
addresses 17 – 23.  Refer to Setting The Touchpad 
Options.   
•  Touchpad keys are continuously backlit for convenience. 
•  Permanent display backlighting is an option on some 
controls (refer to the control panel’s instructions for 
details). 
•  Voice Chime should only be enabled when used with 
control panels that support the "chime by zone" mode (e.g., 
SAFEWATCH PRO/SECURITY MANAGER 3000).  This 
mode  must  be  enabled  at  the  control  panel.    Refer  to  the 
control panel's installation and setup guide for 
information on how to program the chime mode.   
•  Use only zone descriptors supported by this Touchpad.  If 
using zone descriptors not supported by this Touchpad, 
you must turn voice status and voice chime off.  Table 1 is 
a list of applicable zone descriptors and index entries.  
Refer to the control panel’s installation and setup guide 
for information about how to program zone descriptors.   
TOUCHPAD DISPLAYS AND LEDS 
The Touchpad provides a two-line alphanumeric display and 
custom zone descriptors.  The following table identifies the 
Touchpad’s LEDs and associated functions:  
LED Function 
ARMED 
Lights red when the system is armed in any mode. 
READY 
Lights green when the system is "ready" to be 
armed. 
MESSAGE 
Flashes red when message waiting or lights 
(steady) when in record mode. 
PROGRAMMABLE FUNCTION KEYS 
The Touchpad's programmable function keys [A, B, C] are 
normally used for Touchpad panic functions, but they can be 
programmed for other special functions instead.  If they are 
programmed for other special functions, the associated 
Touchpad key pairs still provide the respective panic alarm 
(if programmed).  Refer to the control panel’s Installation & 
Setup Guide for details.  
Function 
Keys
 
Equivalent Key Pairs
 
A
 
[1] and [*]
 
B
 
[*] and [#]
 
C
 
[3] and [#]
 
D
 
NONE 
 
 
•  Function  keys  must  be  held  down  for  at  least  2 
seconds to activate the programmed function.  
• 
If functions other than panics are assigned to the 
programmable function keys, programmed panics must 
be initiated by pressing the programmed key pair.
 
FUNCTION KEY LABELS 
A set of adhesive-backed labels with some typical function 
symbols (i.e., fire, police, personal emergency, etc.) is 
provided.  These labels can be placed on or next to the keys 
to identify each key's function for the end user (as 
determined by the capability and programming of the 
control panel; refer to the installation and setup guide for 
the control panel).
 
6160vADT
-50-001-V0
MOUNTING RELEASE SNAPS
(Remove case back by pushing up the 2 "snaps" along
the keypad's bottom edge and pulling the case apart.)
SIDE VIEW
1
2
3
4
5
6
7
8
9
0
#
STAY
BYPASS
CHIME
INSTANT
AWAY
CODE
TEST
OFF
READY
ARMED
READY
MIC
MESSAGE
RECORD
VOLUME
PLAY
STATUS
FUNCTION
VOICE
A
B
C
D
 
WIRING AND INSTALLATION 
Touchpads can be surface mounted using drywall anchors or 
to a single- or double-gang electrical box.  
1.  Remove the case back by pushing in the two "snaps" 
along the Touchpad’s bottom edge and pulling the case 
apart.  See diagram above. 
2.  Route wiring from the control panel through the opening 
in the case back. 
3.  Mount the case back to a wall or electrical box.  
 
Do not connect the ECP Data In or Data Out until 
directed to do so. If the Prox Reader detects the 
presence of ECP Data In and Out connections during 
address programming mode, it will exit to “normal” 
mode. The touchpad addresses being used for the 
touchpad and the Prox Reader must be enrolled in the 
control panel. 
SEE PAGE 4 FOR FCC & IC STATMENTS