Honeywell International Inc. 8DL6160VPADT Manuale Utente

Pagina di 4
- 2 - 
4.  Wire directly from the Touchpad’s terminal block to the 
terminal block on the control panel. (Refer to Wiring 
Table). Connect only the red and black Aux. Power 
connections at the control panel. 
Wiring Table 
Touchpad 
Control Panel 
Wire Color 
G Data 
In 
Green 
– 
– Aux Pwr (GND) 
Black 
+ Aux. Pwr (POS) 
Red 
Y Data 
Out 
Yellow 
5.  Re-attach the Touchpad to the case back. 
6.  Remove clear protective film from LCD display. 
SETTING THE TOUCHPAD OPTIONS 
The procedures that follow are used to set the Touchpad 
address, voice chime mode, and additional voice Touchpad 
mode. 
Setting the Touchpad Address  
 
When used with the Safewatch Pro/Security Manager 
3000 control panels, address 16 must be assigned to 
the first Touchpad.  Additional Touchpads must be 
set at 17 - 23 and must be enabled additionally in 
control programming (fields *190 - *196).   
The Touchpad may be set for address 00-30 or for non-
addressable mode (31).  The default Touchpad address is 31.  
For valid address settings for your Touchpad, refer to the 
control panel's Installation & Setup Guide. 
Notes: 
•  If unable to enter the address mode, power down, power 
up, and try again. 
•  If 10 seconds pass with no key entry, the Touchpad 
automatically exits the address mode.  You must power 
down, power up, and start the address mode again. 
•  The Touchpad will not enter the address mode if the 
control panel is in programming mode. 
1.  Apply power to the Touchpad. 
2.  Within 60 seconds of applying power to the Touchpad, 
press and hold down the [1] and [3] keys at the same time 
for 3 seconds.  The current Touchpad address will be 
displayed.   
3.  Press "00". The current address is cleared. 
4.  Enter desired two-digit Touchpad address. 
5.  Press [
✱] to accept the displayed address and enter the 
Voice Chime Mode.  "VOICE CHIME" is displayed along 
with the selected mode "1" or "0". 
Setting The Voice Chime Mode 
 
Setting Voice Chime mode off does not effect the 
voice status or alarm annunciation. 
 1. Press [1] to set the Voice Chime mode on or press [0] to 
set the Voice Chime mode off. 
2. Press [
✱] to save the displayed Voice Chime mode and 
enter the Additional Console Voice Touchpad mode. 
 
"ADDITIONAL CON" is displayed along with the 
selected mode "1" or "0". 
 
Setting the Additional Console Mode   
The Additional Console mode must be set for all voice 
Touchpads being used. 
1. Set the voice Touchpad Additional Console mode as 
follows: 
a.  On the Primary voice Touchpad, press [0] to set the 
Additional Console mode to NO. 
b.  On any secondary voice Touchpads, press [1] to set 
Additional Console mode to YES. 
2. Press [
✱] to save the mode and enter Prox Address Mode. 
Setting the Prox Reader Address 
1. After exiting “touchpad address” mode, the prox reader 
will begin communicating with the touchpad, and the 
touchpad will display “Prox Addr? XX” on the first line.  
 
XX = the current ECP Address. 
2. Enter an appropriate ECP address. Set the current 
address to "00":  Press [0] to clear the current "tens" 
digit.  The cursor moves to the "ones" digit position.  
Press [0] to clear the current "ones" digit.  The cursor 
moves back to the "tens" digit position.  
3.  Enter the appropriate address:  Enter the proper "tens" 
digit of the address.  The cursor moves to the "ones" digit 
position.  Enter the proper "ones" digit of the address.   
4.  Press the * key to save the entry. The keypad will beep 
three times confirming the address is accepted, and the 
first digit of the address will flash. You can re-enter the 
address if desired.  
5.  Power down the Touchpad. 
6.  Connect the green and yellow data in and data out wires 
at the control panel. Once connected, any touchpad not 
enabled in the control at that point will be blank. 
 
ENROLLING PROX TAGS 
Each prox tag is enrolled as a “User” in the alarm system. 
When enrolling the tags, the last four digits of the tag’s 
serial number should be used as the User Code. Refer to the 
control’s User Guide for instructions on programming user 
codes. When programming is complete, test the system to 
ensure that each prox tag arms and disarms the system as 
specified. 
VIEWING THE TOUCHPAD ADDRESS 
During normal operation, press and hold down the [1] key 
and [3] key at the same time for about 3 seconds.  The 
current address is displayed.  No key entry is allowed.  Press 
any key to exit or wait 10 seconds to exit the viewing mode. 
SPECIFICATIONS 
Physical: 
5-5/16"H x 7-3/8"W x 1-3/16"D 
Display: 
2 x 16 Alpha-Numeric 
 
Supertwist LCD (backlit) 
Sounder: 
Speaker 
Electrical: 
Voltage:  
+12VDC 
Current: 
  190mA (ARMED LED lit, LCD backlight 
and sounder on) reduces to 60mA when 
panel is operating in standby mode 
(backlight off).