Data Field Descriptions 
 
47
 
Phone System Select 
 
 
Central 
 
Dialing Mode 
 
Station Pulse Tone Pulse Tone 
No 
WATS 
0 = No 
Speaker 
Phone 
Call Wait 
Cancel 
Disabled 
1 = No 
Speaker 
Phone 
Call Wait 
Cancel 
Disabled 
 4 = With 
Speaker 
Phone 
Call Wait 
Cancel 
Disabled 
5 = With 
Speaker 
Phone 
Call Wait 
Cancel 
Disabled 
WATS 
2 = No 
Speaker 
Phone 
Call Wait 
Cancel 
Disabled 
3 = No 
Speaker 
Phone 
Call Wait 
Cancel 
Disabled 
6 = With 
Speaker 
Phone 
Call Wait 
Cancel 
Disabled 
7 = With 
Speaker 
Phone 
Call Wait 
Cancel 
Disabled 
No 
WATS 
8 = No 
Speaker 
Phone 
Call Wait 
Cancel 
Enabled 
9 = No 
Speaker 
Phone 
Call Wait 
Cancel 
Enabled 
 12 = with 
Speaker 
Phone 
Call Wait 
Cancel 
Enabled 
13 = 
With 
Speaker 
Phone 
Call Wait 
Cancel 
Enabled 
WATS 
10 = No 
Speaker 
Phone 
Call Wait 
Cancel 
Enabled 
11 = No 
Speaker 
Phone 
Call Wait 
Cancel 
Enabled 
14 = With 
Speaker 
Phone 
Call Wait 
Cancel 
Enabled 
15 = With 
Speaker 
Phone 
Call Wait 
Cancel 
Enabled 
 
 
 
 
 
 
This option is used to enter the correct type of phone dialing (pulse or tone), 
and to select the correct WATS line option for the Central Station. It is also 
to activate the Speaker Phone option and to disable call waiting. 
 
Call waiting warning tones can interfere with Central stations reporting. 
The Call Waiting Cancel option should be selected if the reporting phone 
line has call waiting service. The Call Waiting Cancel command must also 
be programmed in Field *40. If the Call Waiting Cancel feature is enabled, 
make sure to enter Call Waiting Cancel command in Field *40. The 
command depends on a telephone service provider. 
 
Important Note: If Call Wait Cancel is disabled in Field 
✻47, and Call 
Waiting Disable command is entered in  Field 
✻40, this 
will prevent successful communication to the central 
station when used on a non-call  waiting line.   
 
Notes: (1) PABX number and operation of the control  panel with a PBX 
system cannot be used if the Call Waiting Cancel option has 
been enabled in Field 
✻47. 
  
(2) 
If using pulse dialing, you must enter the numbers slowly in 
order to allow the pulse dialer time to operate. 
48
 
Report Format for Primary/Secondary 
 
Primary Secondary 
See choices below 
See choices below 
0 = 3+1; 4+1 ADEMCO Low Speed Standard 
1 = 3+1; 4+1 Radionics Standard 
2 = 4+2 ADEMCO Low Speed Standard 
3 = 4+2 Radionics Standard 
5 = ADEMCO Contact ID® Reporting with 10-digit 
subscriber account number 
6 = 4+2 ADEMCO Express 
7 = ADEMCO Contact ID® Reporting with 4-digit 
subscriber account number 
8 = 3+1; 4+1 ADEMCO Low Speed Expanded 
9 = 3+1; 4+1 Radionics Expanded 
 
Enter 
 as the 4th digit of 
43 through 
44, if 3+1 dialer reporting is to be 
used. (For an explanation of these formats, see the System Communication 
section of  this manual.) 
Notes:  (1)  The maximum number of alarms is determined by field 
92. 
 
(2)  If Option 5 is selected a 10-digit account number must be 
entered in Fields 
43 or 
44. 
 
(3)  Option 5 or 7  (ADEMCO Contact ID® Reporting) must be 
selected for AVM.