Data Field Descriptions 
 
57
 
False Alarm Options 
 
 
 
Value 
Cancel  
Alarm  
Display 
 
Auto Stay 
Arming 
Exit Time 
Restart/ 
Reset 
=  Disabled Disabled Disabled 
1 = 
Disabled 
Disabled 
Enabled 
=  Disabled Enabled Disabled 
3 = 
Disabled 
Enabled 
Enabled 
4 = 
Enabled 
Disabled 
Disabled 
=  Enabled Disabled Enabled 
6 = 
Enabled 
Enabled 
Disabled 
=  Enabled Enabled Enabled 
 
 
 
 
 
 
 
 
 
 
Note: The control  validates the data entered in this field. If the selection is 
not valid the control will emit a single long beep indicating that the 
selection has been rejected. The control replaces the selection with 
the default value which is displayed on the keypad. 
 
Cancel Alarm Display 
This option enables the display of aborted and cancelled alarms on the 
LYNXR-ENSIA keypad. “CA” will be displayed. 
 
Notes:  1.  An abort occurs if the alarm panel is disarmed before it dials the 
alarm report to the central station.  
 
2.  A cancel occurs if the alarm panel is disarmed after the alarm is 
reported.  
 
3.  Zone types 5, 6 and 7 (panic zone types) and 24 (silent burglary) 
cannot be cancelled. 
 
Auto Stay Arming 
If this feature is enabled and the control panel has been armed “Armed 
Away” at the LYNX keypad or RF keypad, the system will switch to the 
“Armed Stay” mode if the Exit Time has expired and no exit has been 
made. 
 
Exit Time Restart-Exit Delay Restart/Reset 
This option allows the systems to restart the exit delay time 
after arming in STAY mode by entering the User Code and pressing the 
STAY key (if quick arming is disabled) or by pressing the STAY key (if 
quick arming is enabled).  This option also enables automatic exit delay 
reset, which resets exit delay if the entry/exit door is re-opened and closed 
before exit delay time expires after arming.  
 
Notes:  1.  This avoids the need to disarm and then re-arm the system after 
allowing someone to enter or exit.   
 
2.  Automatic Exit Delay Reset occurs only once during an armed 
period. 
58
 
RF Jam Detection 
0 = no jam detection 
1 = RF jam detection with event logging, but no 
central station report 
2 = RF jam detection with event logging and with 
central station report (if trouble/restore report is 
enabled in fields ✻60, ✻71) 
 
For Event Logging, Option 2 must be selected. 
If the control detects an RF jam condition, a “FAULT” message appears for 
zone 90. The Contact ID® code for RF Jam is 344.  
 
 
59
 
Exit Error Report Code 
(Always enabled, a report code can be entered if 
reporting formats other than Contact ID 
® 
are used) 
 
 
 
If the system is armed and an entry/exit or interior zone is still open after 
the exit delay time has expired, an alarm will sound at the keypad and 
external sounder (the keypad will also display “EA”) , and the entry delay 
begins. If the system is disarmed before the end of the entry delay that 
immediately follows, the alarm sounding will stop and no message will be 
sent to the central station. The keypad will display “CA “(CANCELED 
ALARM) if the cancel display option was enabled in field 
✻57. 
If the system is not disarmed before the end of the entry delay mentioned 
above, and an entry/exit or interior zone is still open, an “Exit Alarm” 
message and a “Zone Alarm” message  will be sent to the central station.  
The keypad will display “EA (EXIT ALARM),” and the alarm sounding will 
continue until the system is disarmed (or timeout occurs). 
If Contact ID® format has been programmed, the message will contain the 
zone number and error code 374  (Alarm–Exit Error).  
 
SYSTEM STATUS AND RESTORE REPORT CODES PROGRAMMING (
✻60-✻69, ✻70-✻76, ✻89) 
Program Report Codes using the interactive 
56 Enhanced Zone Programming Mode, or codes can be entered in data 
fields 
60-
69, 
70-
76, 
89. The following is a set of guidelines when programming report codes.  The actual report 
code digits that you enter depend upon the particular installation, and should be in agreement with you and the central 
station office receiving the signals.  
 
With a 3+1 or 4+1 Standard Format:  Enter a code in the first box: 1–9, A, B, C, D, E, or F.  Enter "#+10" for A 
(reports a “0” on some receivers), "#+11" for B, "#+12" for C, "#+13" for D, "#+14" for E, "#+15" for F. Entering "0" in the 
first box will disable a report. Entering "0" in the second box results in automatic advance to the next field. 
 
With an Expanded or 4+2 Format: Enter codes in both boxes (1st and 2nd digits) for 1–9, or A–F, as described above. 
Entering "0" in the first box will disable a report. Entering "0" in the second box will eliminate the expanded message for 
that report. 
 
With ADEMCO Contact ID® Reporting:  Enter a digit in the first box to enable the zone to report.  Use a different 
digit for each zone until you have used up available digits.  If the number of zones exceeds the number of available 
digits, begin with digit 1 again.  This is an "enabling" code only and is not the actual code sent to the central station 
office. Entries in the second boxes will be ignored.  For system status (non-alarm) codes, enter a “1” in the first box for all 
the system conditions you want to send to the central station. A "0" in the first box disables the report.