PRÜFTECHNIK Condition Monitoring GmbH VCRFBR24 Manuale Utente

Pagina di 76
49
VIBCONNECT RF 05.2012
> 15
Ø 27
0.5±2
> 12
M8
90°
Mounting sensor with screw adapter
t
ools
 
and
 
auxiliary
 
equiPment
•  Power drill with two drill bits (3.5 / 6.8 mm) and depth gauge 
•  Spot facer
•  M8 bottoming tap
•  Size 19 torque spanner 
•  Compressed air to clean mounting point
i
nstallation
Select drilling point:
•  The minimum distance between the drill hole and the protruding 
edges of the sensor housing is 35 mm. Ensure that there is suf-
ficient space for the socket wrench used to tighten the adapter.
Drill hole:
•  Using the 3.5 mm drill bit with depth gauge, pre-drill a hole of 
> 15 mm.
•  Drill out hole with 6.8 mm drill bit. 
•  Face the drill hole with the spot facer (depth: approx. 1 mm). 
•   Cut the thread (M8), thread length: > 12 mm. 
Note
Ensure that it is permissible to 
drill a hole at the selected loca-
tion. For instructions, contact the 
machine manufacturer or refer 
to the machine documentation.
Installation and commissioning
adhesive
VIB 3.418
magnetic
VIB 3.423
screwed (M8)
VIB 3.480, standard
Drilling and facing hole, 
cutting thread