Adjustment tips for the operating menu
23
Entering a name – “
NAME
Via the “
NAME
” menu, you can enter a freely selectable name for the transmitter. This name can
be displayed on the standard display and can consist of up to six characters such as:
letters (without pronounciation marks),
numbers from 0 to 9,
special characters and spaces.
After you have changed to the setting mode of the “
NAME
” menu, the first segment starts
flashing on the LC display panel
.
Adjusting the microphone sensitivity – “
ATTEN
Via the “
ATTEN
” menu, you can adjust the transmitter’s sensitivity.
Slide the multi-function switch
 to the position
(UP) or
(DOWN) to select a character. 
(By sliding the switch only once, the display jumps either forwards or
backwards to the next character. If you keep the switch slid, the
display starts cycling continuously.)
Press the multi-function switch
 (switch position 
SET
) to change
to the next segment.
Have you entered the name completely? Press the multi-function
switch
 (switch position 
SET
) to store your setting. “
STORED
appears on the LC display panel.
The sensitivity is correctly adjusted when the level display for audio
signal “AF”
 shows full deflection only during the loudest passages
or when the red LED 
 lights up brightly.
The sensitivity can be adjusted in 1-dB steps from +40 dB to –30 dB.
SET
DOWN
UP
 
dB
AF
RF
The bargraph has a resolution of approx. 3 dB per segment with
a display range of 45 dB.
SK 5212-II_535300_0909_Sp7.book  Seite 23  Dienstag, 22. September 2009  4:07 16