3、ECU Function Description:
3.18. Selectable function ON/OFF:
A). Initial mode Key in cylinder, IGN OFF , Door close then Door close /open two cycle
within 10 sec. then IGN OFF/ON three cycle ,in result LED remain lighted.
B). Push the LOCK in transmitter and switch the setting item in sequence. LED flashed one
to eight times to indicate different function:
C). Siren sounded once represented selected function effected; siren sounded twice
represented selected function terminated.
D). After function selected, to open then close door once and function will be switched from
ON to OFF or from OFF to ON. Siren will sound as above mentioned.
1).
F
lashing 1 time represented Automatic ARM;(initial is “OFF”)
2).
F
lashing 2 times represented Auto-locking on 20km/hr speed and Auto-unlock on
IGN OFF(initial is “ON”)
3).
F
lashing 3 times represented the function of interior lamp delay; (initial is “ON”)
4). Flashing 4 times represented security activating select N=6(initial is “OFF”)
5). Flashing 5 times represented security activating select N=9(initial is “OFF”)
6). Flashing 6 times represented automatic arming trigger delayed time select after T=15
5). Flashing 5 times represented security activating select N=9(initial is “OFF”)
6). Flashing 6 times represented automatic arming trigger delayed time select after T=15
(initial is “OFF”)
7). Flashing 7 times represented automatic arming trigger delayed time select after T=30
(initial is “OFF”)
8). Flashing 8 times represented Auto-closed power window(initial is “OFF”)
Push the LOCK and UNLOCK once simultaneously
9). Flashing 9 times represented setting failure indication if hood/trunk not closed.
Push the LOCK and UNLOCK once simultaneously
9). Flashing 9 times represented setting failure indication if hood/trunk not closed.
(initial is “OFF”)
E). Exit function mode
:
IGN ON or all doors didn’t close or open within 30 seconds or LOCK on transmitter not
Pushed within 30 seconds, then LED OFF and exit function SELECT mode
Pushed within 30 seconds, then LED OFF and exit function SELECT mode
☆3.19. Auto-closed Power Window:
A). After push LOCK ON transmitter within 3 sec push LOCK button again, system
accessed the “Auto-closed Power Window”.
B). After release LOCK button on Transmitter within 3 sec push LOCK button again,
system will function again “Auto-closed Power Window”
☆3.20. Intrusion Sensor OFF:
System accessed ARM status and transmitted ENCODER signal to INTRUSION Sensor
C/U, detection activated after 5 seconds.
Under detection, motion in chamber triggered system to transmit DECORDER signal And
system activated.
C/U, detection activated after 5 seconds.
Under detection, motion in chamber triggered system to transmit DECORDER signal And
system activated.
☆3.21. Smart Entry function:
After detect handle SW dignal, TVSS C/U will transmit encoder signal to SMART ENTRY
C/U which will transmit a remote detecting signal, if exist matching transmitter, which will
transmit UNLOCK signal to TVSS C/U.
C/U which will transmit a remote detecting signal, if exist matching transmitter, which will
transmit UNLOCK signal to TVSS C/U.