Uniden America Corporation UB375 Manuale Utente

Pagina di 112
 
80 
Close Call
 
Your scanner's Close Call feature lets you set the scanner so it detects, alerts you 
to, and displays the frequency of a nearby strong radio transmission. You can set 
the scanner so the Close Call feature checks for a Close Call hit every 2 seconds 
in the background while you are scanning, searching, listening to the weather 
frequency, etc. or use Close Call Only mode. Close Call 
‘Do-Not-Disturb' will only 
check for close call signals when you are not receiving transmissions. You can 
also select the frequency band(s) to look for transmissions. When the scanner 
detects a Close Call hit, it alerts you according to the alert settings. 
 
 
'Hits with Scan' is a special system that automatically stores the last 10 Close Call 
hits until you cycle power. 
 
 
The Close Call feature works well for locating the source of strong local 
transmissions such as mobile and handheld two-way radios in areas with no other 
strong transmission sources. Performance is increased with higher transmit 
power, a receive antenna tuned to the target band, and a low background RF 
level.
 
 
The Close Call feature works better with some types of transmissions than others. 
It might not correctly display frequency information for transmitters using a highly 
directional antenna (such as an amateur radio beam antenna) or if there are 
many transmitters operating at the same time in the same area.  
 
Close Call Options
 
Important! There are many options and settings in Search/Close Call Options 
that affect and compliment the settings for Close Call. Please review those first. 
Press Menu. Scroll to Close Call and press E/yes.
  
 
 
 
 
 
 
 
 
 
Close Call Only 
this setting puts the scanner in Close Call Only mode.  
You will see activity on the 7 bands in the display. Bands with a * (asterisk) under 
them are turned off. 
 
Use the numbers on the keypad to toggle bands On or Off.
 
  
You can also start Close Call Only mode by:  
(BCD536HP) Press and hold SQ( ).  
(BCD436HP) Hold on any channel and press Func then press and hold 
Avoid/ .