Honeywell International Inc. 9PGTPL-100A Manuale Utente

Pagina di 180
Page 1037
1 Mar 2006
34-45-54
MAINTENANCE MANUAL
TPL-100A Processor / Part No. 940-0530-001
Use or disclosure of information on this page is subject to the restrictions in the proprietary notice of this document.
Figure 1012.  Pressure Altitude Display Screen Example
4
Roll
An example of a Roll display is shown in Figure 1013. Line 2 shows the data 
from ARINC 429 Mag Heading/Attitude data bus (label 325).  The (+) 
indicates that data source is the active source.  If the roll data from the 429 
data source is not correct, then line 2 can show INVALID.  Line 3 shows the 
data from a roll attitude synchro.  In this case the data is incorrect.
Figure 1013.  Roll Display Screen Example
5
Pitch
An example of a Pitch display screen is shown in Figure 1014.  Line 2 shows 
the data from ARINC 429 Mag Heading/Allotted data bus (label 324).  The (+) 
shows that source is the active source.  If the Pitch data from the 429 data 
source is not correct, then line 2 shows INVALID.  Line 3 shows the data from 
a Pitch attitude synchro.  In this case the data is correct.
Figure 1014.  Pitch Display Screen Example