Page 1039
1 Mar 2006
34-45-54
MAINTENANCE MANUAL
TPL-100A Processor / Part No. 940-0530-001
Use or disclosure of information on this page is subject to the restrictions in the proprietary notice of this document.
Figure 1017.  Air/Ground Display Screen Example
(b) Mode-S Address
Pushing the Select button when Mode-S Address is the Active Selectable Item on 
the Input screen causes the Mode-S Address display screen to display. Figure 
1018 shows an example of the Mode-S Address screen.  Line two shows the 
hexadecimal address of transponder No. 1 received from XT Coordination No. 1 
(pins RMP 14F and RMP 14G) ARINC 429 data bus (labels 275 and 276).  If the 
data words are not received, no address is shown and that area of the screen 
stays blank.
Figure 1018.  Typical Mode S Transponder Display Screen
(c) Continuous Wave Interference
Pushing the Select button when the Continuous Wave (CW) Interference is the 
Active Selectable Item on the Input Screen, causes the CW Interference display 
screen to be shown. Figure 1019 shows an example of a CW Interference display 
screen.  Line two shows the external CW Internal.  If the external CW 
Interference is between -1 and 0, then NONE is shown. GO BACK is the Active 
Selectable Item. 
Figure 1019.  Continuous Wave Interference Display Screen