FAULT ISOLATION
1. General
A. Description for -0101, -0202, and -0303 Only
(1) Fault isolation is the process of isolating the source of a system failure to an LRU (line 
replaceable unit) or to the aircraft wiring.
(2) For the -1101 and -1212 units, the front panel display indicates the status of the unit. The 
top LED  shows the internal status and shows RED with an internal fault. The center LED 
is normally off and when displaying RED indicates an external failure with either the 
ARINC 429 inputs or unit strapping. The bottom LED shows RED if there is a problem 
with  the antenna connection. A separate connector on the units can be used with an 
adapter to show the indications and functionality described below with the LCD 
functions. The LEDs show amber during the self test function described in the following 
procedure.
(3) Fault isolation in the DMA-37B DME System includes a continuity check of the 
interwiring, and the assurance that proper installation techniques and procedures have 
been followed.
(4) A functional self test of the LRU can be initiated by pressing the test key pushbutton 
switch as designated on the front panel LCD, see Figure 1001. Although the 
normal-mode screen indicates that this actuated from the right key, the left key has the 
same function if pressed while the DMA-37B is in its normal mode.
(5) A complete functional test of the system can be performed as described in the 
MAINTENANCE PRACTICES section of this manual.
(6) Figure 1002 illustrates the control flow of the LCD screens (except for the data loading 
and data recording screens).
Figure 1001. Typical Normal Mode Screen