Honeywell International Inc. DMA-37B2 Manuale Utente

Pagina di 77
Page 1003
10 Oct 2007
34-51-02
MAINTENANCE MANUAL
DMA-37B DME System
© Honeywell International Inc. Do not copy without express permission of Honeywell.
B. Selt-Test Mode for -0101, -0202, and -0303 Only
(1) The self-test mode starts by displaying the Test in Progress screen, see Figure 1003, 
one second after pressing the test key. This is displayed for four seconds with a moving 
thermometer along the bottom of the LCD indicating the progress of the test from one to 
five seconds.
Figure 1003. Test in Progress Screen
(2) The Normal Mode screen (Figure 1001) is displayed for the first second of the test 
sequence.
(3) Once complete, the Test Complete, No Failures screen is displayed (Figure 1004), or 
the Test Complete, Failures screen is displayed (Figure 1005). Both screens contain two 
key selections each: MAINT and RETURN or MAINT and WHY?, respectively.
• MAINT
For both screens, MAINT is located on the left key. This allows the 
initiation of the extended maintenance pages of the system for 
troubleshooting. Refer to Paragraph D.
• RETURN In the Test Complete, No Failures screen, the RETURN key to the right 
returns the system to its normal mode screen (Figure 1001).
•  WHY?
In the Test Complete, Failures screen, the WHY? key to the right puts 
the system into the display-failures mode where individual system 
failures are displayed one on each page. Refer to Paragraph C.
(4) While in the self-test mode, not pressing either key for five minutes causes the system 
to return to the Normal Mode screen (Figure 1001).