Honeywell International Inc. WLUWIFIM010 Manuale Utente

Pagina di 20
CAGE CODE: 
97896 
SCALE: NONE   
SIZE: A 
DWG NO.  
 
REV:  
 
SHEET 10 
HIF-1472R6(1) 
7.2. 
Component Description 
The WLU is shown in Figure 6-1 and the WLU specifications and tolerances are listed below in Tables 7-2. 
Table 7-3 gives the environmental categories that the WLU is tested to. Table 7-4 gives the electromagnetic 
categories that the WLU is tested to. Table 7-4 gives the FCC license requirements this equipment meets or 
exceeds. 
Table 7-2 WLU Leading Particulars 
Parameter  
Specification 
Dimensions (maximum): 
 
 
 Height  
2.5 in. (68.5 mm) 
 
 Width. 
6.85 in. (174.0 mm) 
 
 Length  
11.5 in. (292.1 mm) 
 
 
Weight (maximum)  
4.0 lb (2.3 kg) 
 
 
Power Requirements: 
 
 
Nominal 
28 V dc 
 
Maximum 
29.5 V dc 
 
Minimum  
22 V dc 
 
 
Average Power Dissipation (DC) 
Less than 10 W 
                       
 
Cooling Requirements: 
 
 
The WLU is passively cooled 
Max Operating Temp = 80 degree C 
 
 
Connectors: 
 
 
J1  
See SYSTEM INTERFACES 
 
J2  
See SYSTEM INTERFACES 
 
 
Mounting:
 
 
See MECHANICAL INSTALLATION 
 
The WLU is a bolt-down package 
 
 
Table 7-3 Environmental Categories 
Test Name 
DO-160D 
Category 
Boeing Requirements 
Ground Survival Low Temperature 
Test 
4.5.1 
A1 
-55°C, non-powered. 
Short-Time Operating Low 
Temperature Test 
4.5.1 
A1 
-40°C to -15°C, over a period of 30 Minutes. Degraded 
operation may include no RF Tx. 
Operating Low Temperature Test 
4.5.2 
A1 
-15°C 
Ground Survival High Temperature 
Test 
4.5.2 
A1 
+85°C, unpowered. 
Short-Time Operating High 
Temperature Test 
4.5.3 
A1 
+70°C 
Operating High Temperature Test 
4.5.4 
A1 
+70°C 
Altitude Test 
4.6.1 
A1 
-2,000 ft to +25,000 ft, 2 hours. 
Decompression Test 
4.6.2 
A1 
+6,000 ft to +25,000 ft, reduction within 15 seconds, 
maintain for 10 minutes. 
Overpressure Test 
4.6.3 
A2 
28 PSIA (  196 kPa) 
Temperature Variation 
5.0 
-15°C to +70°C; +2°C/min; 24 cycles. 
Humidity 
6.0 
DO-160E Standard Humidity Environment, 2 cycles. 
Bench Handling Shock 
N/A 
N/A 
D6-81926 Rev G, Section 3.1 
Shipping Container Shock 
N/A 
N/A 
D6-81926 Rev G, Section 3.2 
Acceleration 
N/A 
N/A 
D6-81926 Rev G 
Section 4.1, Zone 1 (Acceleration Load Factors) 
Section 4.2 (Emergency Landing Loads) 
Vibration 
Boeing 
Req. 
Boeing 
Req. 
D6-81926 Section 6, Zone 4, Category C 
Waterproofness 
10.0 
DO-160E 
 
 
Table 7-4 Power and EMC Categories