2. SPECIFICATIONS
1
2.1 GENERAL
Dimensions (Height x Width x Depth):
XG-100LPA:
2.68 x 8.8 x 9.3 inches (6.81 x 22.4 x 23.6 centimeters)
(Includes bracket but not space required for cables)
XG-100LPA and XG-100M:
7.3 x 8.8 x 9.3 inches (18.5 x 22.4 x 23.6 centimeters)
(Includes bracket but not space required for cables)
Control Head, CH-100:
3.3 x 7.0 x 2.8 inches (8.4 x 17.8 x 7.1 centimeters)
(Does not include bracket and mounting screws)
Control Head, CH721:
2.4 x 6.9 x 3.9 inches (6 x 17.5 x 10 centimeters)
(Does not include bracket and mounting screws)
Weights
XG-100LPA and XG-100M:
13.6 pounds (6.17 kilograms), does not include bracket
Control Head, CH-100:
1.20 pounds (0.54 kilograms), does not include bracket
Control Head, CH-721:
1.25 pounds (0.57 kilograms), does not include bracket
Mounting Brackets:
1.25 pounds (0.57 kilograms) each
Cable, Interface:
1.25 pounds (0.57 kilograms)
Operating Ambient Temperature Range:
-22 to +140° Fahrenheit (-30 to +60° Celsius)
Storage Temperature Range:
-40 to +185° Fahrenheit (-40 to +85° Celsius)
Altitude
Operating:
15,000 feet (4572 meters) maximum
Storage/Shipment:
50,000 feet (15,240 meters) maximum
DC Supply Voltage Operating Range
For Full Performance:
+13.6 Vdc ±10% (Normal range per TIA-603)
Overall Operating Range:
+10.8 to +16.6 Vdc
Continuous without Damage:
0 to +17 Vdc
DC Supply Current (less control head and Unity mobile)
XG-100LPA
Receive:
1.1 amps maximum
Transmit at 30 Watts, VHF-Low:
7.25 amps typical, 10 amps maximum
Transmit at 100 Watts, VHF-High:
15 amps typical, 25 amps maximum
Quiescent/Off Current:
2 milliamps maximum
1
These specifications are primarily intended for the use of the installation technician. See the appropriate Specifications
Sheet for the complete specifications.