Telrad Networks Ltd COMPACT23X Manuale Utente

Pagina di 99
Chapter 2 - CommissioningActivating the Unit
Chapter 2: Commissioning
Activating the Unit
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
BreezeCOMPACT System Manual
BreezeCOMPACT System Manual
40
4
Define Antenna Associations.
After properly completing the steps above, the unit will start operating using default values for all other parameters. 
Additional parameters should be configured according to Radio Network Planning (RNP) guidelines and other instructions 
provided by the System Administrator.
This section includes the following sub-sections:
2.5.1
Creating the BS
2.5.1.1
Using the Monitor Program
Select BS > Add. You are prompted to configure the following mandatory parameters:
BS Number (must be 1)
BS ID LSB (must be unique in the Radio Access Network)
Operator ID
Cell ID
Segment Number
Total Uplink Duration
Basic Map Repetition
DL Data Permutation Base
UL Feedback zone Permutation base
UL Data Permutation Base
Bearer IP Address
Paging Group ID (if other than 0, should be unique in the Radio Access Network)
Refer to 
 for details about these parameters.
2.5.1.2
Using the Management System
1
Right-click the BS node in the navigation tree and select Create to open the New BS window. In the current release, only 
the BS Number 1 option is available for BS Number. Configure the following parameters:
BS ID LSB: Must be unique in the Radio Access Network.
Operator ID: The default is 255.243.41. The same Operator ID should be used for all BSs in the Radio Access 
Network.