5 M4-2000 Installation and Configuration
This chapter describes installation, alignment and configuration of M4-2000 units for wireless
bridge operation.
bridge operation.
NOTE: This device must be professionally installed.
5.1 Unit installation
Before field installation, it is recommended that the units be preconfigured at a staging area.
Following are the pre-installation configuration procedures.
Following are the pre-installation configuration procedures.
5.1.1 Configuring a PC for Management of M4-2000 Units
Follow these steps to configure a management PC for communication with a M4-2000 unit:
1. On a Windows PC, select Control Panel > Network and Internet > Network and Sharing
Center > Local Area Connection. For other operating systems, simply go to network and
TCP/IP settings
TCP/IP settings
2. Select Properties > Internet Protocol Version 4 (TCP/IPv4) > Properties
3. Configure the management IP address
3. Configure the management IP address
4. Set IP address to 192.168.0.x where x is any host number except 51 (the default M4-2000
factory preprogrammed IP host address)
5. Set Subnet mask to 255.255.255.0
6. Leave the Default Gateway blank
6. Leave the Default Gateway blank
7. Click OK to save configuration
5.1.2 Connecting a Management PC to a M4-2000 unit
Follow these steps to connect the management PC to the M4-2000 unit:
1. Connect the Management PC’s Ethernet port to the M4-2000 unit Management port (the left
most Ethernet port when facing the unit) using a standard Ethernet cable
2. Apply PoE power to the M4-2000 unit
3. Allow approximately 60 seconds for the unit to boot
3. Allow approximately 60 seconds for the unit to boot
4. Start the web browser on the Management PC
5. Type the default M4-2000 IP address 192.168.0.51 into URL address field. The unit’s Login
5. Type the default M4-2000 IP address 192.168.0.51 into URL address field. The unit’s Login
page is displayed: