Kwikbit Inc. PTP55DP Manuale Utente
M4-2000
User Guide
Kwikbit M4-2000 User Guide
Confidential & Proprietary
- 38 -
6.1.1 Management Home
After login, users arrive at the Management Home Page. To return to the Home from any other page,
click on either the Home link in the left navigation bar or the Kwikbit logo in the upper left corner of
click on either the Home link in the left navigation bar or the Kwikbit logo in the upper left corner of
the page.
The main page displays airlink status and configuration information, as well as Ethernet and airlink
throughput. The airlink can be started, stopped and restarted using the buttons in the upper right of
throughput. The airlink can be started, stopped and restarted using the buttons in the upper right of
the main page.
The airlink status table shows Downlink and Uplink status for each radio and from the perspective
The airlink status table shows Downlink and Uplink status for each radio and from the perspective
of both the local and remote. This display is continually updated approximately every 2 seconds.
TX power – displays transmit power into antenna ports, horizontal (H) and vertical (V), for
local and remote units for all radios
ATPC – Automatic Transmit Power Control status, active or disabled, for all local and
remote antenna ports
RSL – Received Signal Level in dBm on antenna inputs of local and remote units
CINR – Carrier to Interference plus Noise Ratio in dB on all local and remote antennas. This
is a very good indication of the received signal quality
Tx MCS – Modulation and Coding Scheme of transmitted signal from horizontal and vertical
antennas of local unit to remote unit. The MCS can be configured manually, but will more
likely be adjusted automatically by the system when configured for Adaptive MCS
likely be adjusted automatically by the system when configured for Adaptive MCS
Rx MCS – Modulation and Coding Scheme of received signal from horizontal and vertical
antennas of local unit