ICOM 301500 Manuale Utente
q PASSBAND TUNING CONTROLS [TWIN PBT]
Adjust the receiver’s DSP filter passband width.
Adjust the receiver’s DSP filter passband width.
(p. 46)
•
The limit of the variable range depends on the pass-
band width and mode. The limit of the variable range
is half of the passband width, and PBT is adjustable in
25 Hz steps.
band width and mode. The limit of the variable range
is half of the passband width, and PBT is adjustable in
25 Hz steps.
What is the PBT control?
Generally, the PBT electronically narrows the IF
passband width to reject interference. This trans-
ceiver uses the DSP circuit for the PBT function.
passband width to reject interference. This trans-
ceiver uses the DSP circuit for the PBT function.
PBT2
PBT1
Low cut
High cut
Center
TWIN PBT
TWIN PBT
TWIN PBT
–
+
w NOISE BLANKER KEY
NB
(p. 49)
± Push to turn the noise blanker function ON or
OFF.
•
“
” appears on the display.
± Push and hold for 1 sec to enter the noise
blanker set mode; push again to return to normal
operation.
operation.
•
Before entering the noise blanker set mode, the
noise blanker function is turned ON.
noise blanker function is turned ON.
What is the noise blanker?
The noise blanker reduces pulse-type noise such
as that generated by automobile ignition systems.
This function is not effective against non pulse-type
noise.
The noise blanker reduces pulse-type noise such
as that generated by automobile ignition systems.
This function is not effective against non pulse-type
noise.
e NR KEY
NR
(p. 50)
± Push to turn the noise reduction function ON or
OFF.
•
“
” appears on the display.
± Push and hold for 1 sec. to enter the noise re-
duction level set mode; push again to return to
normal operation.
normal operation.
•
Before entering the noise reduction set mode, the
noise reduction function is turned ON.
noise reduction function is turned ON.
What is the Noise Reduction function?
The Noise Reduction (NR) function removes ran-
dom noise from the receiver passband. The level is
adjustable to allow maximum clarity without harm-
ing the intelligibility of the desired signal. Noise Re-
duction should generally not be used with digital
modes.
The Noise Reduction (NR) function removes ran-
dom noise from the receiver passband. The level is
adjustable to allow maximum clarity without harm-
ing the intelligibility of the desired signal. Noise Re-
duction should generally not be used with digital
modes.
1
1
PANEL DESCRIPTION
i7200
MODE
TUNER
TS
FILTER
SPCH
V/M
A/B
SPLIT
M-CL
SCAN
SET
ATT
P.AMP
COMP
VOX
MNF
RIT
1
2
3
4
5
6
7
8
0
50
28
18
14
10
21
24
=
7
3.5
1.8
F-INP
M-CH/RIT
ENT
BAND
GENE
9
.
AGC
MW
ANF
METER
NR
NB
Speaker
t
r
e
w
Function
Display (p. 7)
Display (p. 7)
u
i
y
q
o
N Front panel