ICOM 325100 Manuale Utente
9
3
BASIC OPERATION
■ Audio mute function
This function temporarily mutes the audio without dis-
turbing the volume setting.
turbing the volume setting.
➥ Push [FUNC]
then [
SQL
Y
D(MUTE)]
to
mute the audio.
• The “MUTE” icon appears.
•
•
Push [CLR]
to cancel the function.
■ Squelch attenuator
The transceiver has an RF attenuator related to the
squelch level setting. Approximately 20 dB of attenua-
tion is obtained at the maximum setting.
squelch level setting. Approximately 20 dB of attenua-
tion is obtained at the maximum setting.
Turn ON the Squelch Attenuator function:
q Push [ ] to turn OFF the power.
w While holding down [LOCK] (SET), hold down [ ] for
q Push [ ] to turn OFF the power.
w While holding down [LOCK] (SET), hold down [ ] for
1 second to turn ON the power and enter the Initial
Set mode.
Set mode.
e Push [SET] or [MONI] one or more times, to select
the “SQL” item.
r Rotate [DIAL] to select “AT” (Attenuator).
t Push [ ] to exit the Initial Set mode.
y Rotate [SQL] clockwise further than the 12 o’clock
t Push [ ] to exit the Initial Set mode.
y Rotate [SQL] clockwise further than the 12 o’clock
position, to activate the squelch attenuator.
•
The attenuation level can be adjusted up to 20 dB
(approximately), between the 12 o’clock and fully
clockwise positions.
(approximately), between the 12 o’clock and fully
clockwise positions.
•
When setting the squelch from the microphone, the
level greater than ‘18’ activates the squelch attenuator.
level greater than ‘18’ activates the squelch attenuator.
NOTE: When using with the Monitor function.
The squelch attenuator functions even when the
Monitor function is in use. It is recommended to set
[SQL] between 10 and 12 o’clock (7 to 17 level when
it is set using the HM-133V).
Monitor function is in use. It is recommended to set
[SQL] between 10 and 12 o’clock (7 to 17 level when
it is set using the HM-133V).
■ S-meter squelch
The transceiver has an S-meter squelch. The S-meter
squelch allows you to set minimum signal level needed
to open the squelch.
squelch allows you to set minimum signal level needed
to open the squelch.
Turn ON the S-meter Squelch function:
q Push [ ] to turn OFF the power.
w While holding down [LOCK] (SET), hold down [ ] for
q Push [ ] to turn OFF the power.
w While holding down [LOCK] (SET), hold down [ ] for
1 second to turn ON the power and enter the Initial
Set mode.
Set mode.
e Push [SET] or [MONI] one or more times, to select
the “SQL” item.
r Rotate [DIAL] to select “SS” (S-meter squelch).
t Push [ ] to exit the Initial Set mode.
y Rotate [SQL] clockwise further than the 12 o’clock
position, to activate the S-meter squelch.
LOCK
SET
ANM
MONI
DUP
LOW
T-SCAN
TONE
PRIO
M/CALL
SCAN
V/ MHz
DIGITAL PRIO AO
MUTE
NAR
MID
LOW
NAR
MID
LOW
LOCK
SET
ANM
MONI
DUP
LOW
T-SCAN
TONE
PRIO
M/CALL
SCAN
V/ MHz
ATT
AO
NAR
MID
LOW
MID
LOW
While the squelch attenuator is turned ON.
([DIAL] is set between the 12 o’clock and fully clockwise positions.)
([DIAL] is set between the 12 o’clock and fully clockwise positions.)
Appears
LOCK
SET
ANM
MONI
DUP
LOW
T-SCAN
TONE
PRIO
M/CALL
SCAN
V/ MHz
S SQL
NAR
MID
LOW
MID
LOW
While the S-meter squelch is turned ON.
([DIAL] is set between the 12 o’clock and fully clockwise positions.)
([DIAL] is set between the 12 o’clock and fully clockwise positions.)
Appears
LOCK
SET
ANM
MONI
DUP
LOW
T-SCAN
TONE
PRIO
M/CALL
SCAN
V/ MHz
DIGITAL PRIO AO
BUSY
MUTE
NAR
MID
LOW
MID
LOW
Appears
Mute
Push then .
LOCK
SET
ANM
MONI
DUP
LOW
T-SCAN
TONE
PRIO
M/CALL
SCAN
V/ MHz
DIGITAL PRIO AO
MUTE
NAR
MID
LOW
NAR
MID
LOW
S-meter squelch
1
00
2
3
4
5
6
7
8
9
10
11
12
13