ICOM 325300 Manuale Utente

Pagina di 96
55
9
SET MODES
D Priority watch (PRIO)
Activates priority watch or priority watch with alert (Bell).
  
(default: 
OFF)
• OFF
: The priority watch is turned OFF.
• On
: The transceiver checks the memory channel frequency 
every 5 seconds.
• bELL
: The transceiver checks the memory channel frequency 
every 5 seconds. You can be alerted with beeps and 
blinking “
S.”
D Scan pause timer (PAUSE)
Selects the scan pause time. When receiving signals, the 
scan pauses according to the scan pause timer. (default: 10)
• 2–20
: Scan pauses for 2–20 seconds while receiving a signal 
in 2 seconds steps.
• HOLd : Scan pauses on a received signal until it disappears. 
D Scan resume timer (RESUME)
Selects the scan resume time from a pause after the received 
signal disappears.
(default: 2)
• 0
: Scan resumes immediately after the received signal 
disappears.
• 1–5
: Scan pauses 1–5 seconds after the received signal dis-
appears.
• HOLd
: Scan remains paused on the received signal according 
to the scan pause timer even if it disappears. Rotate 
[DIAL] to resume manually.
Scan resume timer must be set shorter than scan pause 
timer (previous item), otherwise this timer cannot be acti-
vated.
D Program skip scan (P SKIP)
Sets programmed skip scan function ON (default) or OFF for 
VFO scan (full scan, programmed scan, etc.) operation.