10
OPTION INSTALLATIONS
 UT-106  
dsp
 
unit
 
 Optional IF filters
The UT-106 provides AF DSP functions such as 
noise reduction and auto notch.
q
  Remove the top and bottom covers.
w
  Remove the shielding plate.
e
  Remove  the  connection  cable  (P1241)  from 
J1221 on the MAIN unit. Connect the cable into 
J1 on the UT-106.
r
  Plug the connection cable (P1) from the UT-106 
to J1221 on the MAIN unit.
t
  Plug the flat cable into J3 on the UT-106 and to 
J1231 on the MAIN unit.
  • Take care of the conductor direction.
y
  Attach the Velcro tape as shown at right. Attach 
the UT-106 to the reverse side of the MAIN unit.
u
  Return the shielding plate, top cover and bottom 
cover to their original positions.
UT-106
P1241
P1241
J1221
J1231
J3
Several IF filters are available for the IC-R75. You 
can install 1 filter for both 9 MHz and 455 kHz IF. 
Choose appropriate filter for your operating needs.
9 MHz optional filters:
FL-101 
cw
 
narrow
 
filter
 
250 Hz/–6 dB
FL-232 
rtty
/
cw
 
narrow
 
filter
 
350 Hz/–6 dB
FL-100 
cw
 
narrow
 
filter
 
500 Hz/–6 dB
FL-223 
ssb
 
narrow
 
filter
 
1.9 kHz/–6 dB
FL-103 
ssb
 
wide
 
filter
 
2.8 kHz/–6 dB
455 kHz optional filters:
FL-53A 
cw
 
narrow
 
filter
 
250 Hz/–6 dB
FL-52A 
cw
/
rtty
 
narrow
 
filter
 
500 Hz/–6 dB
FL-222 
ssb
 
narrow
 
filter
 
1.8 kHz/–6 dB
FL-96 
ssb
 
wide
 
filter
 
2.8 kHz/–6 dB
FL-257 
ssb
 
wide
 
filter
 
3.3 kHz/–6 dB
D Installation
q
  Remove the top cover as shown on the opposite 
page.
w
  Install the desired 9 MHz filter as shown in the 
diagram below.
  • The filters can be installed in either direction.
e
  Install the desired 455 kHz filter as shown in the 
diagram below.
r
 Replace the top cover.
  After filter installation, specify the installed filter 
using  filter  set  mode.  (p.  19)  Otherwise,  the 
installed filter will not function properly.