ICOM IC-R75 Manuale Utente

Pagina di 48
37
11
MAINTENANCE
CIRCUITRY FUSE REPLACEMENT
The 13.8 V DC from the DC power cable is applied 
to all units in the IC-R75 through the circuitry fuse. 
This fuse is installed in the MAIN unit.
q
  Remove the top cover as shown on p. 34
w
  Replace  the  circuitry  fuse  as  shown  in  the 
diagram at right.
e
  Replace the top cover.
FGB 3 A
 Fuse replacement
If a fuse blows or the receiver stops functioning, try 
to find the source of the problem, and replace the 
damaged fuse with a new, rated fuse.
  
CAUTION:
 DISCONNECT the DC power cable 
from the receiver when changing a fuse.
The IC-R75 has 2 types of fuses installed for receiver 
protection.
• DC power cable fuses  
 FGB 3 A
• Circuitry fuse  
 FGB 3 A
DC POWER CABLE FUSE REPLACEMENT
3 A fuse
 Clock backup battery replacement
The receiver has a lithium backup battery (CR2032) 
inside for clock and timer functions. The usual life of 
the backup battery is approximately 2 years.
When the backup battery is exhausted, the receiver 
receives normally but cannot retain the current time.
CR2032
e
r
q
w