5.3.4.3
 
LIMITER REGULATION 
 
In these sub-menus an upper limit for the output signal deviation can be enabled and regulated. 
The menu Limiter permits to enable or disable the limiter, if the limiter is enabled the value can be 
regulated in the next menu.   
 
 
 
Fig. 5.23 – Enable limiter menu 
 
To enable/disable the limiter press the OK key to enter the program mode (blinking arrow in second 
row on the right). Press UP or DOWN keys to select the on/off state. Press OK key to confirm or 
ESC key to exit routine without saving.  
In case the Limiter is enabled the green led LIM on the frontal panel will switched on. 
 
To adjust the limiter value, press DOWN key to select the Limiter value sub-menu. 
 
 
Fig. 5.24 – Limiter value menu 
 
To change the limiter value, press the OK key to enter the program mode (blinking arrow in second 
row  on  the  right).  Press  UP  or  DOWN  keys  to  select  the  new  value.  Press  OK  key  to  confirm  or 
ESC key to exit routine without saving.  
The limiter value is applied in real time and only if the limiter is enabled. 
 
MIN value: 30 KHz 
MAX value: 180 KHz 
STEP: ±1 KHz 
Table 5.5 – Limiter permitted values