DB ELETTRONICA TELECOMUNICAZIONI S.P.A. MOZART500 Manuale Utente

Pagina di 87
 
 
35 /87
5.3.5
 
SENSITIVITY MENU 
 
In  this  menu  it  is  possible  to  set  the  sensitivity  value  in  of  all  available  unit  input  channels,  the 
sensitivity level will induce a regulation of channels internal attenuators.    
A sensitivity value equal to the relative channel input level will cause an output signal deviation of 
75 KHz in case of mono signal or 71 KHz in case of stereo signal.   
To navigate in this sub-menu press UP or DOWN keys until the channel desired. 
 
 
 
 
 
 
 
 
 
Fig. 5.25 – Channels Sensitivity 
 
To  change  the  sensitivity  level,  press  the  OK  key  to  enter  the  program  mode  (blinking  arrow  in 
second row on the right). Press UP or DOWN keys to increase or decrease the value. Press OK key 
to confirm or ESC key to exit routine without saving.  
The sensitivity value is applied in real time and only if the relative channel is in ON state (see menu 
Operat.Mode). 
 
CHANNELS 
MIN value 
MAX value 
STEP 
LEFT, RIGHT 
0 dBu 
+15 dBu 
±0.05 dB 
AES-EBU LEFT, RIGHT 
-10 dBFS 
0 dBFS 
±0.05 dB 
MPX Ext 
0 dBu 
+15 dBu 
±0.05 dB 
RDS, SCA, AUX 
-16 dBu 
0 dBu 
±0.5 dB 
Table 5.6 – Sensitivity permitted values