5.3.7.1
 
WARNING FOLDBACK REFLECTED POWER 
 
The  unit  is  provided  with  a  reflected  power  level  proportional  protection:  in  case  the  output 
reflected  power  exceeds  the  foldback  threshold  value  the  unit  enters  in  warning  mode  and  the 
output forward power is proportionally lowered to maintain the reflected power under the foldback 
threshold level.  
The  folbadck  threshold  is  indicated  as  percentage  of  nominal  unit  power.  Standard  factory 
calibration is 15% of nominal power. 
 
 
Fig. 5.37 – Foldback Reflected menu 
 
To  change  the  foldback  threshold  level,  press  the  OK  key  to  enter  the  program  mode  (blinking 
arrow in second row on the right). Press UP or DOWN keys to select desired value. Press OK key 
to confirm or ESC key to exit routine without saving. 
 
MIN value: 0% 
MAX value: 100% 
STEP: ±1% 
Table 5.13 – Foldback Reflected permitted values 
 
 
5.3.7.2
 
WARNING REFLECTED POWER 
 
In this menu it is possible to set a threshold value for a reflected power warning in similar way to 
the previous menu.  
The  presence  of  this  warning  does  not  alter  in  any  way  the  output  forward  power  unlike  by  the 
foldback reflected warning.    
The Warning Reflected threshold is indicated as percentage of nominal unit power.  
 
 
Fig. 5.38 – Warning Reflected menu