DB ELETTRONICA TELECOMUNICAZIONI S.P.A. MOZART500 Manuale Utente

Pagina di 87
 
 
46 /87
 
5.3.7.4
 
ALARM POWER LOW 
 
In this menu it is possible to set an alarm in case the forward power level drops below a threshold in 
a similar mode as previous menu.  
In case the forward power never exceeds the Alarm Power Low threshold from the unit switch ON 
the warning is generated after 40 seconds otherwise after 4 seconds. 
The Alarm Power Low threshold is indicated as percentage of nominal unit power.  
 
 
Fig. 5.40 – Alarm power Low menu 
 
To change the Alarm Power Low threshold, press the OK key to enter the program mode (blinking 
arrow in second row on the right). Press UP or DOWN keys to select desired value. Press OK key 
to confirm or ESC key to exit routine without saving. 
 
MIN value: 0% 
MAX value: 100% 
STEP: ±1% 
Table 5.16 – Alarm power Low permitted values 
 
To disable this alarm set the Alarm Power Low to 0%. 
 
 
5.3.7.5
 
AUDIO LOW EVENT 
 
The Audio Low warning/alarm is generated if the audio level at an active input channel drops below 
a threshold set in the menu Audio Low Level for at least T1 seconds.  
In presence of Audio Low warning/alarm in case the audio level exceeds the Audio Low threshold 
for  at  least  T2  seconds  the  warning/alarm  status  is  automatically  ended.  This  warning/alarm  is 
indicated also by the led NO AUDIO switched on in the frontal panel. 
The timeouts T1 and T2 are set in the menus Audio Low T1 and Audio Low T2
 
 
Fig. 5.41 – Audio Low Level menu