DB ELETTRONICA TELECOMUNICAZIONI S.P.A. MOZART500 Manuale Utente

Pagina di 87
 
 
47 /87
 
To  change  the  Audio  Low  level,  press  the  OK  key  to  enter  the  program  mode  (blinking  arrow  in 
second row on the right). Press UP or DOWN keys to select desired value. Press OK key to confirm 
or ESC key to exit routine without saving. 
 
MIN value: -20 dBu 
MAX value: +20 dBu 
STEP: ±0.1 dB 
Table 5.17 – Audio Low Level permitted values 
 
To  setup  the  timeouts  Audio  Low  T1  and  T2  navigate  to  the  relative  menus  with  UP  or  DOWN 
keys. 
 
 
Fig. 5.42 – Audio Low timeout menus 
  
To change the Audio Low timeouts, press the OK key to enter the program mode (blinking arrow in 
second row on the right). Press UP or DOWN keys to select desired value. Press OK key to confirm 
or ESC key to exit routine without saving. 
 
MIN value: 0 sec 
MAX value: 1000 sec 
STEP: ±1 sec 
Table 5.18 – Audio Low timeouts permitted values 
 
To disable this warning/alarm set both the timeouts Audio Low T1 and T2 to 0 sec. 
 
 
5.3.7.6
 
AUDIO OVER EVENT 
 
The Audio Over warning/alarm is generated if the audio level at an active input channel exceeds a 
threshold set in the menu Audio Over Level for at least T1 seconds.  
In  presence  of  Audio  Over  warning/alarm  in  case  the  audio  level  drops  below  the  Audio  Over 
threshold  for  at  least  T2  seconds  the  warning/alarm  status  is  automatically  ended.  This 
warning/alarm is indicated also by the led NO AUDIO switched on in the frontal panel. 
The timeouts T1 and T2 are set in the menus Audio Over T1 and Audio Over T2.  
 
 
Fig. 5.43 – Audio Over Level menu