iData 95 User Manual 
- 24 - 
Œ
  Do not put the battery into a fire.   
Œ
  If the battery leaks, do not let the liquid stain your skin or eyes. Otherwise, wash your 
skin or eyes with lots of water and go to see the doctor immediately.   
Cleaning iData 95 
Œ
 Shell  
Clean the shell by using a cloth soaked with alcohol, including keys and space between 
 keys. 
 
Œ
 Display 
screen 
You can clean the display screen by using a cloth soaked with alcohol. Do not let the 
liquid gather around the screen. Otherwise, dry the screen by using a soft non-woven 
cloth in case strip marks are left on the screen.   
Œ
 Scan 
lens  
Clean the scan lens regularly by using lens paper or other articles suitable for cleaning 
 optical 
materials. 
 
7.2 Troubleshooting 
Table 7-1 iData 95 troubleshooting 
Fault  
Cause 
Solution 
The battery volume is too 
low or the battery is not 
charged.  
Charge the iData 95 or replace the battery. 
The battery is incorrectly 
installed.  
Correctly install the battery.   
After the power key is 
pressed, the iData 95 is 
not powered on. 
The system breaks down. 
Restores factory settings. 
The battery fails. 
Replace the battery. 
Battery charging fails. 
The temperature of the 
battery is too high or low. 
Put the battery in normal temperature. 
The cable configuration is 
incorrect.  
Consult the system administrator.   
During data 
communication, data is 
not transmitted or 
transmitted data is 
incomplete. 
The communication 
software is incorrectly 
installed or configured. 
Install or reinstall the ActiveSync software to 
update the driver. 
The relevant function is 
not activated after a user 
clicks a button or icon. 
The system does not 
respond. 
Restart the system. 
No sound can be heard. 
The volume is too low or is 
disabled. 
Adjust the volume. 
The iData 95 is in the 
inactive state. 
After being inactive for a period of time, the 
iData 95 is closed. 
The iData 95 is closed. 
The battery is used up. 
Replace the battery. 
The iData 95 responds 
Too many files are stored  Remove unused memos and records. If