Note: To check uN•LIme for continued use, place some scale 
or white chalk in a glass with a small amount of uN•LIme.  If 
the material is vigorously dissolved by the uN•LIme, it can be 
reused; if not, the uN•LIme should be replaced.
figure 28.
ignition module system
Before calling your service agent, the following checklist should 
be examined to eliminate obvious problems from those requiring 
replacement or servicing.
•  Check that “main manual gas shutoff valve” is fully open and 
that gas service has not been interrupted.
•  Check  that  after  following  the  appliance  oPerATINg 
INSTruCTIoNS, the “Top Knob” of the appliance gas valve 
is in “oN” position.
•  Check electrical supply to the appliance for possible blown 
(or  tripped)  fusing  or  power  interruption.  Also  check  the  3 
amp fuse on the front of the digital thermostat (fig. 2).
•  Is the water temperature in tank below the thermostat dial 
setting on the appliance thermostat (calling for heat)?
•  It  is  possible  that  the  high  limit  (e.C.o.)  has  functioned  to 
shut off the appliance. See High Limit page 7 - High Limit 
Switch  for  reset  procedure.  Contact  your  service  agent  if 
limit continues to function to shut off appliance. 
system diagnostics
Your  water  heater  is  equipped  with  an  ignition  module  that 
incorporates  a  diagnostic  system  to  assist  in  troubleshooting 
the appliance. The indicator codes on the ignition module are 
as follows:
TABLe 11:
1 fLASH
System lockout (retries or cycles exceeded)
2 fLASHeS Pressure switch stuck close
3 fLASHeS Pressure switch stuck open
4 fLASHeS open on high temperature limit switch (eco)
6 fLASHeS 115 volt AC power reversed (check polarity)
7 fLASHeS Low flame sense signal (make sure flame sensor is in 
burner flame)
8 fLASHeS Check igniter
continuous  flash  ->  continuous  flame  sensed  >  5  seconds 
without gas valve
continuous on -> internal control failure - replace ignition control module.
use this diagnostic system in conjunction with “oPerATIoNAL 
CHeCKLIST”  and  the  “SequeNCe  of  oPerATIoN”  to 
troubleshoot the appliance. 
8.  remove the cleanout cover and place a clean plastic bucket 
next to the cleanout opening.
Partially  open  the  cold  water  inlet  valve  to  allow  time  to 
accomplish the following and then close the valve.
While  the  water  is  being  run  through  the  tank,  insert  a 
stiff wire, copper tube flattened at one end or an opened 
wire  coat  hanger  through  the  cleanout  opening  and 
scrape out any loose deposits of scale or sediment. This 
is an economical way to avoid unnecessary usage of the 
deliming solution.
repeat the opening and closing of the cold water inlet valve 
as necessary but be sure the heater is completely drained 
when ready to introduce the uN•LIme.
upon completion, reinstall the cleanout cover and use a new 
cleanout cover gasket (part number 9004099215).
remove the drain valve.
9.  Install the long plastic male adapter insert fitting into the drain 
valve opening of heater after applying Teflon tape or paste to 
threads. Tighten firmly by hand and use wrench or adjustable 
pliers to check for secure connection. Do not over tighten to 
avoid damage to threads and fittings.
Prepare the up-N-Down Transfer Kit
The next step is the preparation on the up-N-Down Transfer Kit, 
if you have not already done so:
1.  With  the  5  gallon  up-N-Down  container  in  the  vertical 
position,  unscrew  the  plastic  vent  cap  in  the  handle  and 
pierce  the  plastic  membrane  over  the  vent  boss  under  the 
cap to allow the container to vent.
note: If your container does not have the vent cap and vent 
boss, drill a 3/16” hole in the handle.  When you have finished 
deliming  you  will  be  able  to  plug  this  drilled  vent  with  the 
stainless steel screw that is supplied with the kit.
2.  remove the container’s cap and cut the plastic membrane 
located in the 3/4” IPT opening in the cap.  Take care to not 
damage the threads.
3.  find the 3/4” male adapter, apply teflon tape to the threaded 
end and screw it into the 3/4” IPT opening in the cap.
4.  Put cap with male adapter back on the container and slide  
3/4” hose over end of male adapter and fasten in place using 
hose clamp provided.
Delime using flo-Jug method
5.  Slide the hose clamp over end of hose and slide hose over 
the  male  adapter  in  the  water  heater  drain  opening  and 
secure in place using hose clamp.
6.  Lift  container  to  the  “Pour”  Position,  see  figure  28,  being 
careful to keep the vent in the handle above the liquid level 
and pour the uN•LIme into the heater.
7.  Lower container, you may have to place the container on its 
empty carton to prevent the uN•LIme from flowing back into 
the container.
8.  Let  uN•LIme  remain  in  the  heater  for  5  minutes  and  then 
lower the container to the “Drain” Position, see figure 28.
9.  Deliming activity is indicated by foaming on the surface of the 
uN•LIme. If there is deliming activity, repeat steps 6 thru 8.
Normally,  lime  removal  will  be  completed  within  one  hour.  
Severe build-up of lime may take longer than an hour to complete 
descaling.